Product Details | CONTROL TRANSFORMER SYNCHRO

5990-00-068-3592 A synchro consisting of a stator and rotor inductively coupled. The electrical output of the rotor is dependent upon both the position of the rotor and the electrical input to the stator from a transmitter synchro or a differential synchro. Does not include variable resistors, goniometers, or variable transformers.

Part Alternates: AY975B1, 68D40024, 5990-00-068-3592, 00-068-3592, 5990000683592, 000683592

Electrical and Electronic Equipment Components | Synchros and Resolvers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-068-3592

Drawings & Photos | NSN 5990-00-068-3592


Cross Reference | NSN 5990-00-068-3592

Part Number Cage Code Manufacturer
68D40024 97151 AIR FORCE LOGISTICS COMMAND 88 0SS OSE
AY975B1 55972 HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS
AY975B1 96774 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5990-00-068-3592

Technical Data | NSN 5990-00-068-3592

Characteristic Specifications
BODY SIZE 12
STATOR INPUT VOLTAGE RATING IN VOLTS 10.2 NOMINAL
STATOR INPUT CURRENT RATING 86.0 MILLIAMPERES NOMINAL
STATOR INPUT ELECTRICAL POWER RATING 170.0 MILLIWATTS NOMINAL
FREQUENCY IN HERTZ 400.0 NOMINAL
ZRO IMPEDANCE MAGNITUDE IN OHMS 777.50 NOMINAL
ZRO IMPEDANCE ANGLE IN DEG 77.80 NOMINAL
ZSO IMPEDANCE MAGNITUDE IN OHMS 132.50 NOMINAL
ZSO IMPEDANCE ANGLE IN DEG 78.85 NOMINAL
ROTOR DC RESISTANCE IN OHMS 95.00 NOMINAL
STATOR DC RESISTANCE IN OHMS 14.00 NOMINAL
TRANSFORMATION RATIO 2.206 ROTOR TO STATOR NOMINAL
PHASE SHIFT ANGLE IN DEG 5.500 INPUT TO OUTPUT NOMINAL
MAXIMUM TEMP RISE 30.0 DEG CELSIUS
MAXIMUM TOTAL NULL VOLTAGE OUTPUT IN MILLIVOLTS PER VOLT 28.00
ELECTRICAL ERROR ANGULAR RANGE IN MINUTES -10.0 TO 10.0
ACTUATOR FRICTION TORQUE AT MINUS 55 DEG CELSIUS 55.00 INCH-OUNCES NOMINAL
ACTUATOR FRICTION TORQUE AT PLUS 25 DEG CELSIUS 11.00 INCH-OUNCES NOMINAL
BODY STYLE A12 STANDARD ROUND, ROTATABLE STATOR C
SHOULDER DIAMETER 1.0000 INCHES NOMINAL
PILOT DIAMETER 0.6250 INCHES NOMINAL
OVERALL LENGTH 2.8450 INCHES NOMINAL
FLANGE DIAMETER 1.1880 INCHES NOMINAL
FLANGE THICKNESS 0.0930 INCHES NOMINAL
UNDERCUT DIAMETER 1.0000 INCHES NOMINAL
UNDERCUT WIDTH 0.0500 INCHES NOMINAL
PILOT LENGTH 0.0620 INCHES NOMINAL
SHOULDER LENGTH 0.0620 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.2670 INCHES MAXIMUM
SHAFT TYPE ROUND SINGLE SHAFT
SHAFT DIAMETER 0.1200 INCHES NOMINAL SINGLE SHAFT
SHAFT LENGTH 0.5090 INCHES NOMINAL SINGLE SHAFT
TERMINAL TYPE AND QUANTITY 5 SCREW
TERMINAL LOCATION REAR
BODY MATERIAL STEEL, CORROSION RESISTING
III SHAFT END PLAY 0.0005 INCHES NOMINAL
III SHAFT END PLAY DETERMINING WEIGHT 4.0 OUNCES
III SHAFT MAXIMUM RUNOUT 0.0008 INCHES

Restrictions/Controls & Freight Information | NSN 5990-00-068-3592

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5990-00-068-3592

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Price ValidationV The current standard price has been validated.
  • The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
  • The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
  • ZOP or Standard price challenges are permissible but must be supported by adequate justification.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each