NSN 5915-00-130-1796 39810147, 398-10147, 00-130-1796
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-00-130-1796 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: 39810147, 398-10147, 5915-00-130-1796, 00-130-1796, 5915001301796, 001301796
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 04 DEC 1968 | 00-130-1796 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Cross Reference | NSN 5915-00-130-1796
Part Number | Cage Code | Manufacturer |
---|---|---|
398-10147 | 11530 | LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN INFORMATION |
398-10147 | 13058 | SORA POWER INC. |
398-10147 | 13619 | EMS DEVELOPMENT CORPORATION |
398-10147 | 46859 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN GOVERNMENT |
398-10147 | 60854 | LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN INFORMATION |
398-10147 | 81831 | FILTRON CO INC DIV OF RFI CORP |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-00-130-1796
Technical Data | NSN 5915-00-130-1796
Characteristic | Specifications |
---|---|
INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 1ST RADIO INTERFERENCE 240.0 VOLTS AC 2ND RADIO INTERFERENCE |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 45.0 1ST RADIO INTERFERENCE 66.0 2ND RADIO INTERFERENCE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 1ST RADIO INTERFERENCE 7.0 2ND RADIO INTERFERENCE |
MAXIMUM VOLTAGE DROP PER FUNCTION | 0.5 VOLTS AC 1ST RADIO INTERFERENCE 0.5 VOLTS AC 2ND RADIO INTERFERENCE |
INCLOSURE TYPE | HERMETICALLY SEALED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG INPUT 1 CONNECTOR, RECEPTACLE OUTPUT 2 TAB, SOLDER LUG GROUND |
STYLE DESIGNATOR | 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
OVERALL LENGTH | 17.375 INCHES MINIMUM AND 17.500 INCHES MAXIMUM |
BODY LENGTH | 17.375 INCHES MINIMUM AND 17.500 INCHES MAXIMUM |
BODY HEIGHT | 3.875 INCHES MINIMUM AND 4.000 INCHES MAXIMUM |
BODY WIDTH | 4.875 INCHES MINIMUM AND 5.000 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 16.500 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 4.000 INCHES NOMINAL |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
NOMINAL THREAD SIZE | 0.190 INCHES |
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
III MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
III OUTPUT TERMINAL MANUFACTURER CODE | 71468 |
III OUTPUT TERMINAL IDENTIFICATION | GS02-16S-5P |
III VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 55.0 |
III OPERATING TEMP RANGE | 0.0 TO 71.0 DEG CELSIUS |
III BODY MATERIAL | METAL |
III BODY SURFACE TREATMENT | TIN |
Restrictions/Controls & Freight Information | NSN 5915-00-130-1796
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-130-1796
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | T | Other Electronics Equipment |
Weapons Systems/End Item or Homogeneous Group | TM | Comm Sys Support |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |