NSN 5915-00-131-1047 F20349, F20349A, F9333
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-00-131-1047 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: F20349, F20349A, F9333, 9052331, 905233-1, 5915-00-131-1047, 00-131-1047, 5915001311047, 001311047
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 06 DEC 1968 | 00-131-1047 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-00-131-1047
Technical Data | NSN 5915-00-131-1047
Characteristic | Specifications |
---|---|
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 BLANK |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 BLANK AND 0.5 BLANK |
MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS DC BLANK |
INCLOSURE TYPE | ENCASED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET INPUT 1 TURRET OUTPUT |
STYLE DESIGNATOR | 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
OVERALL LENGTH | 1.750 INCHES MAXIMUM |
BODY LENGTH | 1.120 INCHES NOMINAL |
BODY HEIGHT | 0.687 INCHES NOMINAL |
BODY WIDTH | 1.000 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.437 INCHES NOMINAL |
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
III MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
III AVERAGE LIFE RATING IN HOURS | 10000.0 |
III UNPACKAGED UNIT WEIGHT | 1.500 OUNCES |
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 600.0 VOLTS AT SEA LEVEL |
III VIBRATION RESISTANCE RANGE IN HERTZ | 5.0 TO 2000.0 |
III OPERATING TEMP RANGE | -54.0 TO 95.0 DEG CELSIUS |
III BODY MATERIAL | METAL |
Restrictions/Controls & Freight Information | NSN 5915-00-131-1047
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-131-1047
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |