Product Details | FLOW RATE INDICATING METER

6680-01-252-4693 An instrument for measuring the rate of flow of a fluid through a pipeline. This measurement is indicated on a graduated scale either by means of a float confined in a tube, or pointer connected to a vane, or piston and spring or the like. Excludes METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Part Alternates: 84639A27, 84639A-27, 6680-01-252-4693, 01-252-4693, 6680012524693, 012524693

Instruments and Laboratory Equipment | Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments

Supply Group (FSG) NSN Assign. NIIN
66 03 APR 1987 01-252-4693

Cross Reference | NSN 6680-01-252-4693

Part Number Cage Code Manufacturer
84639A-27 53553 AMETEK INC SCHUTTE AND KOERTING DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6680-01-252-4693

Technical Data | NSN 6680-01-252-4693

Characteristic Specifications
DESIGN TYPE CASE
CONSTRUCTION ARMORED
METERING TUBE QUANTITY 2
SCALE TYPE DIRECT CAPACITY READING
OVERALL LENGTH 42.000 INCHES NOMINAL
MAXIMUM WORKING PRESSURE 3000.0 POUNDS PER SQUARE INCH
SPECIAL FEATURES CONSISTS OF HIGH FLOW TURBINE FLOWMETER, MEDIUM FLOW TURBINE FLOWMETER, LOW FLOW TURBINE FLOWMETER; FLOW RANGE 0.012 TO 12.500 GPM; VALVES AIR OPERATED, ELECTRICALLY ACTUATED; BODY MATERIAL CAST IRON
III PART NAME ASSIGNED BY CONTROLLING AGENCY MANIFOLD SYSTEM,TURBINE FLOWMETER

Restrictions/Controls & Freight Information | NSN 6680-01-252-4693

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information