Product Details | RADIO FREQUENCY REFLECTION ISOLATOR

5985-01-327-3017 A device which allows radio frequency energy to pass in one direction with very little power loss, but blocks the flow of energy in the other direction by means of multiple WAVE-polarization or an integral dissipative load. It isolates frequency sensitive circuity from the effects of reflected radio frequency energy resulting from component mismatch. It usually has one or more ports terminated with coaxial connector(s) and/or waveguide flange(s); or other electrical terminations. Isolators designed for internal use in waveguide runs may consist of rods, rings, chips, strips and the like and have no ports or terminations. See also DIPLEXER; DUPLEXER. Excludes CIRCULATOR, RADIO FREQUENCY.

Part Alternates: G3003911, G300391-1, X9.11, XM360, X911, 42371, 4237-1, 5985-01-327-3017, 01-327-3017, 5985013273017, 013273017

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 11 OCT 1990 01-327-3017

Demand History | NSN 5985-01-327-3017

Part Number Request Date QTY Origin
5985-01-327-3017 2007-12-338 3 DIBBS
5985-01-327-3017 2007-09-264 5 DIBBS
5985-01-327-3017 2007-09-263 3 DIBBS

Cross Reference | NSN 5985-01-327-3017

Part Number Cage Code Manufacturer
4237-1 51735 A AND A ENGINEERING ENTERPRISES
G300391-1 24930 EXELIS INC. DBA RADAR, RECONNAISSANCE & UNDERSEA
X9.11 31791 3DBM CO INC
XM360 14135 E AND M LABORATORIES DIV OF TRAK MICROWAVE CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-327-3017

Technical Data | NSN 5985-01-327-3017

Characteristic Specifications
FREQUENCY RANGE RATING 9.0 TO 9.2 GIGAHERTZ
OVERALL LENGTH 1.925 INCHES MINIMUM
OVERALL WIDTH 1.615 INCHES MINIMUM AND 1.635 INCHES MAXIMUM
OVERALL HEIGHT 0.590 INCHES MINIMUM AND 0.610 INCHES MAXIMUM
FLANGE QUANTITY 1
FLANGE TYPE COVER
FLANGE CONNECTION FACILITY QUANTITY 4
FLANGE CONNECTING HOLE DIAMETER 0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM
IDENTIFICATION DESIGNATOR TYPE UG-135/U
SPECIAL FEATURES VSWR 1.25; INSERTION LOSS 0.50 DB MAX; ISOLATION 18.0 DB MIN; POWER RATING 5.0 W AVG,5000.0 W PEAK; ALUMINUM; CHEMICAL FILM,PRIMER AND PAINT
III FSC APPLICATION DATA ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT

Restrictions/Controls & Freight Information | NSN 5985-01-327-3017

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063520 WAVEGUIDE IN BOXES/CRATES
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 723 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-327-3017

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each