NSN 5950-01-357-9484 15M217CU2, 15M217CU-2, 01-357-9484
Product Details | POWER AUTOTRANSFORMER TRANSFORMER
5950-01-357-9484 A transformer which incorporates the primary and secondary functions into a single winding, which is common to both input and output circuits, and is designed to change the relationship of volts and amperes between the entire winding and its taps. Includes multiple winding transformers of like design and items in which a variation of the turns ratio or inductive ratio of inductive coupling is accomplished by connection to fixed terminals. Also, includes items having a provision for mechanically changing the turns ratio in progressive increments, by means of a shaft, voltage taps, ratio adjuster, or devices of similar design. Excludes TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 15M217CU2, 15M217CU-2, 5950-01-357-9484, 01-357-9484, 5950013579484, 013579484
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 05 MAY 1992 | 01-357-9484 | 36166 ( TRANSFORMER, POWER AUTOTRANSFORMER ) |
Demand History | NSN 5950-01-357-9484
Part Number | Request Date | QTY | Origin |
---|---|---|---|
15M217CU-2 | 2019-01-29 | 1 | DIBBS |
15M217CU-2 | 2019-01-24 | 1 | DIBBS |
5950-01-357-9484 | 2018-09-255 | 1 | DIBBS |
5950-01-357-9484 | 2013-05-139 | 1 | DIBBS |
Cross Reference | NSN 5950-01-357-9484
Part Number | Cage Code | Manufacturer |
---|---|---|
15M217CU-2 | 58474 | SUPERIOR ELECTRIC HOLDING GROUP LLC DBA SUPERIOR ELECTRIC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-01-357-9484
Technical Data | NSN 5950-01-357-9484
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 17 SCREW |
(NON-CORE DATA) WINDING TAP LOCATION | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
WINDING OPERATING VOLTAGE | 480.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT 0.00 AC VOLTS MINIMUM AND 400.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT 480.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY INPUT 0.00 AC VOLTS MINIMUM AND 400.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY OUTPUT |
WINDING OPERATING CURRENT | 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY OUTPUT |
WINDING POWER RATING | 2.4 K1LOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 2 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | SLOT SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 10.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
OVERALL LENGTH | 16.410 INCHES NOMINAL |
OVERALL HEIGHT | 7.250 INCHES NOMINAL |
OVERALL WIDTH | 6.000 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
Restrictions/Controls & Freight Information | NSN 5950-01-357-9484
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-357-9484
Category | Code | Description |
---|---|---|
Cognizance Codes | 3B | Navy-owned stocks of field level repairable DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Reparability | D | Field Level Reparables |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |