Product Details | POWER AUTOTRANSFORMER TRANSFORMER

5950-00-896-9275 A transformer which incorporates the primary and secondary functions into a single winding, which is common to both input and output circuits, and is designed to change the relationship of volts and amperes between the entire winding and its taps. Includes multiple winding transformers of like design and items in which a variation of the turns ratio or inductive ratio of inductive coupling is accomplished by connection to fixed terminals. Also, includes items having a provision for mechanically changing the turns ratio in progressive increments, by means of a shaft, voltage taps, ratio adjuster, or devices of similar design. Excludes TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 51336, 5-1336, 65550-01003-101, 65550-01003-102, 5950-00-896-9275, 00-896-9275, 5950008969275, 6555001003101, 6555001003102, 008969275

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 03 FEB 1967 00-896-9275

Drawings & Photos | NSN 5950-00-896-9275


Demand History | NSN 5950-00-896-9275

Part Number Request Date QTY Origin
5950-00-896-9275 2024-10-295 1 United States
5950-00-896-9275 2024-10-295 2 United States
5950-00-896-9275 2018-09-266 15 DIBBS
5950-00-896-9275 2018-07-185 45 DIBBS
5950-00-896-9275 2018-06-170 25 DIBBS
5950-00-896-9275 2018-05-130 56 DIBBS
5950-00-896-9275 2018-05-129 26 DIBBS
5950-00-896-9275 2018-03-85 16 DIBBS
5950-00-896-9275 2017-11-325 61 DIBBS
5950-00-896-9275 2017-09-263 61 DIBBS
5950-00-896-9275 2017-09-261 3 DIBBS
5950-00-896-9275 2017-06-159 2 United States
5950-00-896-9275 2017-06-157 2 DIBBS
6555-00-100-3102 2015-05-133 1 United States
6555-00-100-3102 2014-12-345 1 US
5950-00-896-9275 2013-03-78 6 United States
5950-00-896-9275 2013-03-73 6 United States
5950-00-896-9275 2012-10-278 1 United States
5950-00-896-9275 2012-10-278 2 United States
5950-00-896-9275 2012-10-278 6 United States
5950-00-896-9275 2012-08-240 6 United States
5950-00-896-9275 2012-08-228 6 United States
6555-00-100-3102 2012-07-206 1 United States
5950-00-896-9275 2012-01-19 2 United States
5950-00-896-9275 2012-01-19 3 United States
5950-00-896-9275 2011-07-206 1 United States
5950-00-896-9275 2011-06-166 1 United States
5950-00-896-9275 2011-05-151 5 United States
5950-00-896-9275 2008-02-36 46 DIBBS
5950-00-896-9275 2007-12-353 45 DIBBS
5950-00-896-9275 2007-12-338 45 DIBBS
5950-00-896-9275 2007-09-247 12 DIBBS
5950-00-896-9275 2007-06-162 16 DIBBS
5950-00-896-9275 2007-04-95 7 DIBBS

Cross Reference | NSN 5950-00-896-9275

Part Number Cage Code Manufacturer
5-1336 58474 SUPERIOR ELECTRIC HOLDING GROUP LLC DBA SUPERIOR ELECTRIC
65550-01003-101 78286 SIKORSKY AIRCRAFT CORPORATION
65550-01003-102 78286 SIKORSKY AIRCRAFT CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-896-9275

Technical Data | NSN 5950-00-896-9275

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 3 THREADED STUD
WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT 0.00 AC VOLTS MINIMUM AND 5.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING CURRENT 18.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED BUSHING SINGLE GROUP
THREAD SERIES DESIGNATOR UNEF SINGLE GROUP
NOMINAL THREAD SIZE 0.375 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 4.070 INCHES MAXIMUM
BODY OUTSIDE DIAMETER 2.000 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
(NON-CORE DATA) DUMMY TERMINAL QUANTITY 2

Restrictions/Controls & Freight Information | NSN 5950-00-896-9275

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-896-9275

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesHDIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesHDIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each