NSN 5945-01-323-6743 M83516/1-044, M835161044, MIL-R-83516/1
Product Details | REED RELAY
5945-01-323-6743 A relay consisting of an energizing coil and a metallic reed switch mechanism. The reeds serve as both core and contacts, which are not hinged or pivoted and which move by flexure when acted upon by a magnetic field induced by energization of the coil. It may also include a biasing magnet. The biasing magnet, either aids or opposes the movement of the reeds and the opening or closing of the contacts. For items in which actuation is dependent on the resonant frequency of the reeds see RELAY, RESONANT REED. Excludes RELAY, ELECTROMAGNETIC.
Part Alternates: M83516/1-044, M835161044, MIL-R-83516/1, MILR835161, 5945-01-323-6743, 01-323-6743, 5945013236743, 013236743
Electrical and Electronic Equipment Components | Relays and Solenoids
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 05 AUG 1990 | 01-323-6743 | 30544 ( RELAY, REED ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5945-01-323-6743
Technical Data | NSN 5945-01-323-6743
Characteristic | Specifications |
---|---|
NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 250.0 MILLIAMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 450.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ENERGIZING ELEMENT POWER RATING | 3.0 VOLTS-AMPERES |
TERMINAL TYPE AND QUANTITY | 7 PIN ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
OVERALL LENGTH | 0.770 INCHES MAXIMUM |
OVERALL WIDTH | 0.290 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
OVERALL HEIGHT | 0.290 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
TEST DATA DOCUMENT | 81349-MIL-R-83516 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-83516/1 GOVERNMENT SPECIFICATION |
III PURPOSE FOR WHICH DESIGNED | GENERAL |
III END ITEM IDENTIFICATION | AN/SWG-3B |
(NON-CORE DATA) END ITEM SOURCE | 76301 |
III CUBIC MEASURE | 0.110 CUBIC INCHES |
III UNPACKAGED UNIT WEIGHT | 2.5 GRAMS |
III FRAGILITY FACTOR | MODERATELY RUGGED |
III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-83516/1 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M83516/1-044 |
Restrictions/Controls & Freight Information | NSN 5945-01-323-6743
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5945-01-323-6743
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |