NSN 5945-01-211-9791 M39016/06-104M, M39016/6-104P, M39016/6-204M
Product Details | ELECTROMAGNETIC RELAY
5945-01-211-9791 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Part Alternates: M39016/06-104M, M39016/6-104P, M39016/6-204M, M3901606104M, M390166104P, M390166204M, M5757/10-005, M5757/10-017, M5757/9-005, M5757/9-006, M575710005, M575710017, M575710057, M5757-10-057, M57579005, M57579006, BRDJ26U1H6AS1 , BRSJ26BL1J6AS1, MIL-PRF-39016/6, MILPRF390166, MIL-R-39016/6, MILR390166, MIL-R-5757/10, MIL-R-5757/9, MILR575710, MILR57579, ERSX2131, ERWKJX360 , EX2AD012, FC1391W, FC1-391W , 654675 , 9741076060, 974-1076-060, 340681, 36RJP2700GSMN, 36RJP2-700G-SMN, 3SAF1898A2 , 3SAV1206A2, 3SAV5132H1, 4644253REVB, 464425-3REVB , 578R040H04 , 578R145H04, ED2A , 5945-01-211-9791, 01-211-9791, 5945012119791, 012119791
Electrical and Electronic Equipment Components | Relays and Solenoids
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 05 JUL 1985 | 01-211-9791 | 32512 ( RELAY, ELECTROMAGNETIC ) |
Demand History | NSN 5945-01-211-9791
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5945-01-211-9791 | 2022-08-216 | 71 | DIBBS |
5945-01-211-9791 | 2022-07-207 | 18 | DIBBS |
5945-01-211-9791 | 2022-07-198 | 75 | DIBBS |
5945-01-211-9791 | 2022-06-181 | 91 | DIBBS |
5945-01-211-9791 | 2022-06-172 | 33 | DIBBS |
5945-01-211-9791 | 2022-03-62 | 40 | DIBBS |
5945-01-211-9791 | 2021-07-211 | 39 | DIBBS |
5945-01-211-9791 | 2021-07-196 | 39 | DIBBS |
5945-01-211-9791 | 2020-07-183 | 78 | DIBBS |
5945-01-211-9791 | 2017-03-64 | 70 | DIBBS |
5945-01-211-9791 | 2017-02-52 | 230 | DIBBS |
5945-01-211-9791 | 2017-02-52 | 92 | DIBBS |
5945-01-211-9791 | 2017-02-40 | 92 | DIBBS |
5945-01-211-9791 | 2015-07-194 | 13 | DIBBS |
5945-01-211-9791 | 2015-05-149 | 97 | DIBBS |
5945-01-211-9791 | 2013-07-190 | 144 | DIBBS |
5945-01-211-9791 | 2012-11-313 | 110 | DIBBS |
5945-01-211-9791 | 2012-10-284 | 46 | DIBBS |
5945-01-211-9791 | 2012-09-245 | 48 | DIBBS |
M57579006 | 2012-07-208 | 30 | CN |
5945-01-211-9791 | 2012-04-114 | 40 | DIBBS |
5945-01-211-9791 | 2012-02-40 | 31 | DIBBS |
5945-01-211-9791 | 2011-06-158 | 1 | United States |
5945-01-211-9791 | 2011-05-139 | 54 | DIBBS |
5945-01-211-9791 | 2011-03-83 | 16 | DIBBS |
5945-01-211-9791 | 2010-12-350 | 37 | DIBBS |
5945-01-211-9791 | 2010-11-316 | 30 | DIBBS |
M390166104P | 2010-06-152 | 47 | Taiwan |
5945-01-211-9791 | 2010-03-81 | 114 | DIBBS |
5945-01-211-9791 | 2009-09-257 | 2 | US |
5945-01-211-9791 | 2009-05-121 | 85 | DIBBS |
5945-01-211-9791 | 2009-02-58 | 136 | DIBBS |
5945-01-211-9791 | 2008-03-70 | 62 | DIBBS |
5945-01-211-9791 | 2008-01-08 | 50 | DIBBS |
5945-01-211-9791 | 2007-11-309 | 47 | DIBBS |
5945-01-211-9791 | 2006-06-177 | 55 | DIBBS |
MILR390166 | 2006-01-31 | 40 | IT |
Cross Reference | NSN 5945-01-211-9791
Part Number | Cage Code | Manufacturer |
---|---|---|
340681 | 26581 | HAMILTON SUNDSTRAND CORPORATION DBA APPLIED SCIENCE OPERATION |
36RJP2-700G-SMN | 78277 | SIGMA INSTRUMENTS INC |
3SAF1898A2 | 01526 | GENICOM CORP |
3SAF1898A2 | 1DUQ5 | COMMUNICATIONS INSTRUMENTS INC DIV OF CII TECHNOLOGIES |
3SAV1206A2 | 01526 | GENICOM CORP |
3SAV1206A2 | 1DUQ5 | COMMUNICATIONS INSTRUMENTS INC DIV OF CII TECHNOLOGIES |
3SAV5132H1 | 01526 | GENICOM CORP |
3SAV5132H1 | 1DUQ5 | COMMUNICATIONS INSTRUMENTS INC DIV OF CII TECHNOLOGIES |
464425-3REVB | 00779 | TYCO ELECTRONICS CORPORATION |
464425-3REVB | 01526 | GENICOM CORP |
464425-3REVB | 02288 | ALLIED CONTROLS, INC. |
464425-3REVB | 10412 | WHITTAKER CORP WHITTAKER ELECTRONIC SYSTEMS DIV |
464425-3REVB | 1DUQ5 | COMMUNICATIONS INSTRUMENTS INC DIV OF CII TECHNOLOGIES |
464425-3REVB | 1E9M5 | C P CLARE CORP |
464425-3REVB | 58614 | TYCO ELECTRONICS CORPORATION DBA CII TECHNOLOGIES |
464425-3REVB | 77342 | TYCO ELECTRONICS CORPORATION |
464425-3REVB | 96214 | RAYTHEON COMPANY DBA RAYTHEON |
464425-3REVB | 99699 | DRI RELAYS INC. DBA FOREIGN PARENT IS FINANCIERE DE |
578R040H04 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS |
578R145H04 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS |
654675 | 05234 | THERMO JARRELL ASH CORP BAIRD DIV |
974-1076-060 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
BRDJ26U1H6AS1 | 99699 | DRI RELAYS INC. DBA FOREIGN PARENT IS FINANCIERE DE |
BRSJ26BL1J6AS1 | 99699 | DRI RELAYS INC. DBA FOREIGN PARENT IS FINANCIERE DE |
ED2A | 58657 | LEACH INTERNATIONAL CORPORATION DBA LEACH INTERNATIONAL NORTH |
ERSX2131 | 02288 | ALLIED CONTROLS, INC. |
ERWKJX360 | 02288 | ALLIED CONTROLS, INC. |
EX2AD012 | 58657 | LEACH INTERNATIONAL CORPORATION DBA LEACH INTERNATIONAL NORTH |
FC1-391W | 78290 | STRUTHERS-DUNN INC |
M39016/06-104M | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M39016/6-104P | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M39016/6-204M | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M5757-10-057 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M5757/10-005 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M5757/10-017 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M5757/9-005 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M5757/9-006 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-PRF-39016/6 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-R-39016/6 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-R-5757/10 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-R-5757/9 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5945-01-211-9791
Technical Data | NSN 5945-01-211-9791
Characteristic | Specifications |
---|---|
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD 750.0 MILLIAMPERES DC INDUCTIVE LOAD 160.0 MILLIAMPERES DC LAMP LOAD |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 1.180 INCHES MAXIMUM |
OVERALL WIDTH | 0.410 INCHES MAXIMUM |
OVERALL HEIGHT | 0.600 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 1.062 INCHES MINIMUM AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
FEATURES PROVIDED | POLARIZED |
SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT |
TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/6 GOVERNMENT SPECIFICATION |
CRITICALITY CODE JUSTIFICATION | FEAT |
III PURPOSE FOR WHICH DESIGNED | GENERAL |
III CUBIC MEASURE | 0.290 CUBIC INCHES |
III UNPACKAGED UNIT WEIGHT | 0.460 OUNCES |
III FRAGILITY FACTOR | MODERATELY RUGGED |
III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
III CASE MATERIAL | METAL |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39016/6 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39016/6-104P |
Restrictions/Controls & Freight Information | NSN 5945-01-211-9791
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | Y | The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5945-01-211-9791
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |