Product Details | REED RELAY

5945-00-424-9321 A relay consisting of an energizing coil and a metallic reed switch mechanism. The reeds serve as both core and contacts, which are not hinged or pivoted and which move by flexure when acted upon by a magnetic field induced by energization of the coil. It may also include a biasing magnet. The biasing magnet, either aids or opposes the movement of the reeds and the opening or closing of the contacts. For items in which actuation is dependent on the resonant frequency of the reeds see RELAY, RESONANT REED. Excludes RELAY, ELECTROMAGNETIC.

Part Alternates: 2622A12VDC, 262-2A12VDC, 855817, 5945-00-424-9321, 00-424-9321, 5945004249321, 004249321

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 19 APR 1971 00-424-9321

Cross Reference | NSN 5945-00-424-9321

Part Number Cage Code Manufacturer
262-2A12VDC 02116 COOPER WHEELOCK INC.
262-2A12VDC 83604 INRESCO INC
855817 1PQF4 L-3 COMMUNICATIONS CORPORATION DBA LINK SIMULATION & TRAINING
855817 36378 RAYTHEON TECHNICAL SERVICES COMPANY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-424-9321

Technical Data | NSN 5945-00-424-9321

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 250.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 0.5 MILLIAMPERES DC RESISTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 720.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 6 PIN ALL FUNCTIONS
DUTY TYPE CONTINUOUS
OVERALL LENGTH 1.438 INCHES NOMINAL
OVERALL WIDTH 0.635 INCHES NOMINAL
OVERALL HEIGHT 0.438 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY

Restrictions/Controls & Freight Information | NSN 5945-00-424-9321

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-424-9321

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each