Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-509-7206 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: RF300704, RF3-0070-4, 83208946000, 832-08946-000, 508-D-9338 ITEM 5, 508D9338ITEM5, 5915-01-509-7206, 01-509-7206, 5915015097206, 015097206

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 01 JUL 2003 01-509-7206

Drawings & Photos | NSN 5915-01-509-7206


Demand History | NSN 5915-01-509-7206

Part Number Request Date QTY Origin
5915-01-509-7206 2014-11-314 16 DIBBS
5915-01-509-7206 2014-10-303 16 DIBBS
5915-01-509-7206 2014-09-264 2 DIBBS
5915-01-509-7206 2014-08-226 2 DIBBS

Cross Reference | NSN 5915-01-509-7206

Part Number Cage Code Manufacturer
508-D-9338 ITEM 5 0EXU3 AQUA-CHEM, INC.
832-08946-000 0EXU3 AQUA-CHEM, INC.
RF3-0070-4 6Z539 MTE CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-509-7206

Technical Data | NSN 5915-01-509-7206

Characteristic Specifications
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 480.0 VOLTS AC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 BLANK
OPERATING CURRENT RATING PER FUNCTION IN AMPS 70.0 BLANK
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 6 SCREW INPUT-OUTPUT AND 2 THREADED STUD GROUND
STYLE DESIGNATOR 30 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 12.300 INCHES NOMINAL
OVERALL HEIGHT 7.500 INCHES NOMINAL
BODY LENGTH 11.730 INCHES NOMINAL
BODY WIDTH 0.700 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.276 MILLIMETERS NOMINAL
III UNPACKAGED UNIT WEIGHT 9.188 POUNDS
III END ITEM IDENTIFICATION POWER PANEL 450VAC 508-D-9338; WSD: OLIVER PERRY CLASS FFG

Restrictions/Controls & Freight Information | NSN 5915-01-509-7206

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-509-7206

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each