Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-406-1515 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: 88051001T, 88051-001T, 5915-01-406-1515, 01-406-1515, 5915014061515, 014061515

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 21 DEC 1994 01-406-1515

Demand History | NSN 5915-01-406-1515

Part Number Request Date QTY Origin
88051001T 2011-06-172 1765 US
5915-01-406-1515 2011-04-100 19 DIBBS
5915-01-406-1515 2011-04-91 19 DIBBS

Cross Reference | NSN 5915-01-406-1515

Part Number Cage Code Manufacturer
88051-001T 037Z3 DLA LAND AND MARITIME OPNS SUPPORT GROUP
88051-001T 59942 AVX FILTERS CORPORATION
88051-001T 66230 PACIFIC AEROSPACE & ELECTRONICS, INC.
88051-001T 79474 GREATBATCH SIERRA INC DBA USE CAGE CODE 58421 FOR

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-406-1515

Technical Data | NSN 5915-01-406-1515

Characteristic Specifications
OPERATING CURRENT RATING PER FUNCTION IN AMPS 100.0 BLANK
WIDTH ACROSS FLATS 0.154 INCHES MINIMUM AND 0.159 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.112 INCHES
BODY LENGTH 0.340 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 PIN INPUT-OUTPUT
SPECIAL FEATURES OPERATING TEMP RANGE AT -55 DEG C TO 125 DEG C
OVERALL LENGTH 0.600 INCHES NOMINAL
INCLOSURE TYPE UNINCLOSED
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 100.0 VOLTS DC BLANK
MAXIMUM VOLTAGE DROP PER FUNCTION 0.2 VOLTS DC BLANK
STYLE DESIGNATOR ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES

Restrictions/Controls & Freight Information | NSN 5915-01-406-1515

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-406-1515

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each