Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-302-4090 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: APFV331L, 5915-01-302-4090, 01-302-4090, 5915013024090, 013024090

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 14 JUN 1989 01-302-4090

Drawings & Photos | NSN 5915-01-302-4090


Cross Reference | NSN 5915-01-302-4090

Part Number Cage Code Manufacturer
APFV331L 00853 CORNELL-DUBILIER MARKETING, INC.
APFV331L 14655 CORNELL-DUBILIER ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-302-4090

Technical Data | NSN 5915-01-302-4090

Characteristic Specifications
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 120.0 VOLTS AC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 BLANK
OPERATING CURRENT RATING PER FUNCTION IN AMPS 10.0 BLANK
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 4 CONNECTOR, PLUG INPUT-OUTPUT
STYLE DESIGNATOR 12 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 3.730 INCHES NOMINAL
OVERALL HEIGHT 1.130 INCHES NOMINAL
BODY WIDTH 2.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.188 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5915-01-302-4090

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information