NSN 5915-01-279-0042 C51080361, C5108036-1, RF12016
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-01-279-0042 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: C51080361, C5108036-1, RF12016, 5915-01-279-0042, 01-279-0042, 5915012790042, 012790042
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 12 MAY 1988 | 01-279-0042 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-01-279-0042
Technical Data | NSN 5915-01-279-0042
Characteristic | Specifications |
---|---|
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE 50.0 OHMS 6TH RADIO INTERFERENCE |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE 50.0 OHMS 6TH RADIO INTERFERENCE |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 1ST RADIO INTERFERENCE 200.0 VOLTS DC 2ND RADIO INTERFERENCE 100.0 VOLTS DC 3RD RADIO INTERFERENCE 100.0 VOLTS DC 4TH RADIO INTERFERENCE 100.0 VOLTS DC 5TH RADIO INTERFERENCE 100.0 VOLTS DC 6TH RADIO INTERFERENCE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 20.0 1ST RADIO INTERFERENCE 20.0 2ND RADIO INTERFERENCE 10.0 3RD RADIO INTERFERENCE 10.0 4TH RADIO INTERFERENCE 10.0 5TH RADIO INTERFERENCE 10.0 6TH RADIO INTERFERENCE |
MAXIMUM VOLTAGE DROP PER FUNCTION | 0.08 VOLTS DC 1ST RADIO INTERFERENCE 0.08 VOLTS DC 2ND RADIO INTERFERENCE 0.25 VOLTS DC 3RD RADIO INTERFERENCE 0.25 VOLTS DC 4TH RADIO INTERFERENCE 0.25 VOLTS DC 5TH RADIO INTERFERENCE 0.25 VOLTS DC 6TH RADIO INTERFERENCE |
INCLOSURE TYPE | ENCASED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 11 TAB, SOLDER LUG OUTPUT 8 TURRET GROUND |
STYLE DESIGNATOR | 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
BODY LENGTH | 2.800 INCHES NOMINAL |
BODY HEIGHT | 2.500 INCHES NOMINAL |
BODY WIDTH | 1.820 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.100 INCHES NOMINAL |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.138 INCHES |
FEATURES PROVIDED | SHOCK RESISTANT |
III PRINCIPAL CIRCUITRY TYPE PER | INDUCTANCE-CAPACITANCE 1ST RADIO |
Restrictions/Controls & Freight Information | NSN 5915-01-279-0042
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-01-279-0042
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |