Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-189-3177 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: A4110, A-4110, 55424621, 5542462-1, 5915-01-189-3177, 01-189-3177, 5915011893177, 011893177

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 14 SEP 1984 01-189-3177

Drawings & Photos | NSN 5915-01-189-3177


Cross Reference | NSN 5915-01-189-3177

Part Number Cage Code Manufacturer
5542462-1 53711 NAVAL SEA SYSTEMS COMMAND
A-4110 23939 THE CAPTOR CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-189-3177

Technical Data | NSN 5915-01-189-3177

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 1ST RADIO INTERFERENCE 115.0 VOLTS AC 2ND RADIO INTERFERENCE 115.0 VOLTS AC 3RD RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 1ST RADIO INTERFERENCE 60.0 2ND RADIO INTERFERENCE 60.0 3RD RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 35.0 1ST RADIO INTERFERENCE 35.0 2ND RADIO INTERFERENCE 35.0 3RD RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 1.15 VOLTS AC 1ST RADIO INTERFERENCE 1.15 VOLTS AC 2ND RADIO INTERFERENCE 1.15 VOLTS AC 3RD RADIO INTERFERENCE
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 3 THREADED STUD OUTPUT 1 THREADED STUD GROUND
STYLE DESIGNATOR 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 11.685 INCHES NOMINAL
BODY LENGTH 9.970 INCHES MINIMUM AND 10.030 INCHES MAXIMUM
BODY HEIGHT 4.000 INCHES MAXIMUM
BODY WIDTH 7.060 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 4 SLOT 6 THREADED HOLE
MOUNTING SLOT WIDTH 0.250 INCHES MINIMUM AND 0.260 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 5.990 INCHES MINIMUM AND 6.010 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNF
NOMINAL THREAD SIZE 0.190 INCHES
FEATURES PROVIDED NUT AND WASHER
SPECIAL FEATURES THREE FILTERED FUNCTIONS
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
III AVERAGE LIFE RATING IN HOURS 10000.0
III INPUT TERMINAL MANUFACTURER CODE 96906
III INPUT TERMINAL IDENTIFICATION MS3406D22-22SX

Restrictions/Controls & Freight Information | NSN 5915-01-189-3177

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-189-3177

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each