Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-188-2557 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: A3322, 10480251, 1048025-1, 5915-01-188-2557, 01-188-2557, 5915011882557, 011882557

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 31 AUG 1984 01-188-2557

Drawings & Photos | NSN 5915-01-188-2557


Cross Reference | NSN 5915-01-188-2557

Part Number Cage Code Manufacturer
1048025-1 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
1048025-1 49956 RAYTHEON COMPANY DBA RAYTHEON
A3322 23939 THE CAPTOR CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-188-2557

Technical Data | NSN 5915-01-188-2557

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 120.0 VOLTS AC 1ST RADIO INTERFERENCE 120.0 VOLTS AC 2ND RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 63.0 1ST RADIO INTERFERENCE 63.0 2ND RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 10.0 1ST RADIO INTERFERENCE 10.0 2ND RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 1.0 VOLTS AC 1ST RADIO INTERFERENCE 1.0 VOLTS AC 2ND RADIO INTERFERENCE
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 2 THREADED STUD OUTPUT
STYLE DESIGNATOR 20 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL HEIGHT 6.161 INCHES NOMINAL
BODY LENGTH 1.630 INCHES NOMINAL
BODY HEIGHT 4.630 INCHES NOMINAL
BODY WIDTH 1.630 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.000 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.138 INCHES
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
III MAXIMUM TEMP RISE 25.0 DEG CELSIUS
III INPUT TERMINAL MANUFACTURER CODE 49956
III INPUT TERMINAL IDENTIFICATION A-10-16-10P-10
III UNPACKAGED UNIT WEIGHT 1.300 POUNDS
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 800.0 VOLTS AT SEA LEVEL
III VIBRATION RESISTANCE RANGE IN HERTZ 10.0 TO 500.0
III OPERATING TEMP RANGE -55.0 TO 85.0 DEG CELSIUS
III BODY MATERIAL METAL
III END ITEM IDENTIFICATION AMPLIFIER,RADIO FREQUENCY AM-7061/WSC

Restrictions/Controls & Freight Information | NSN 5915-01-188-2557

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-188-2557

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each