Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-025-0859 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: GF55625, GF-55625, RF15412, 9055591, 905559-1, 10 B 614, 10B614, 5915-01-025-0859, 01-025-0859, 5915010250859, 010250859

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 26 JUL 1976 01-025-0859

Drawings & Photos | NSN 5915-01-025-0859


Demand History | NSN 5915-01-025-0859

Part Number Request Date QTY Origin
GF55625 2010-05-144 150 China

Cross Reference | NSN 5915-01-025-0859

Part Number Cage Code Manufacturer
10 B 614 13058 SORA POWER INC.
905559-1 06481 NORTHROP GRUMMAN SYSTEMS CORPORATION
GF-55625 07294 GENISCO FILTER CORP.
GF-55625 13050 SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
RF15412 13619 EMS DEVELOPMENT CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-025-0859

Technical Data | NSN 5915-01-025-0859

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 1ST RADIO INTERFERENCE 115.0 VOLTS AC 2ND RADIO INTERFERENCE 115.0 VOLTS AC 3RD RADIO INTERFERENCE 150.0 VOLTS DC 4TH RADIO INTERFERENCE 150.0 VOLTS DC 5TH RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 1ST RADIO INTERFERENCE 60.0 2ND RADIO INTERFERENCE 60.0 3RD RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 32.6 1ST RADIO INTERFERENCE 32.6 2ND RADIO INTERFERENCE 32.6 3RD RADIO INTERFERENCE 42.0 4TH RADIO INTERFERENCE 42.0 5TH RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 2.5 VOLTS AC 1ST RADIO INTERFERENCE 2.5 VOLTS AC 2ND RADIO INTERFERENCE 2.5 VOLTS AC 3RD RADIO INTERFERENCE 500.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 500.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 5 THREADED STUD INPUT 5 THREADED STUD OUTPUT 2 THREADED STUD GROUND
STYLE DESIGNATOR 30 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 9.500 INCHES MAXIMUM
OVERALL HEIGHT 3.000 INCHES MAXIMUM
BODY LENGTH 7.500 INCHES MAXIMUM
BODY WIDTH 6.940 INCHES MINIMUM AND 7.060 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 6 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.218 INCHES MINIMUM AND 0.224 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 8.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 6.125 INCHES NOMINAL
III MAXIMUM TEMP RISE 45.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5915-01-025-0859

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-025-0859

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each