NSN 5915-00-933-5658 DMS 82010B, DMS82010B, JN172675B1
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-00-933-5658 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: DMS 82010B, DMS82010B, JN172675B1, JN17-2675B1, JN172675D1, JN17-2675D1, 7618181, 5915-00-933-5658, 00-933-5658, 5915009335658, 009335658
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 07 SEP 1966 | 00-933-5658 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-00-933-5658
Technical Data | NSN 5915-00-933-5658
Characteristic | Specifications |
---|---|
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE 50.0 OHMS 6TH RADIO INTERFERENCE |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE 50.0 OHMS 6TH RADIO INTERFERENCE |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 1ST RADIO INTERFERENCE 200.0 VOLTS AC 2ND RADIO INTERFERENCE 25.0 VOLTS DC 3RD RADIO INTERFERENCE 25.0 VOLTS DC 4TH RADIO INTERFERENCE 25.0 VOLTS DC 5TH RADIO INTERFERENCE 50.0 VOLTS DC 6TH RADIO INTERFERENCE |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 400.0 2ND RADIO INTERFERENCE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.7 1ST RADIO INTERFERENCE 0.7 2ND RADIO INTERFERENCE 0.025 3RD RADIO INTERFERENCE 0.025 4TH RADIO INTERFERENCE 0.025 5TH RADIO INTERFERENCE 0.025 6TH RADIO INTERFERENCE |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 1ST RADIO INTERFERENCE 1.0 VOLTS AC 2ND RADIO INTERFERENCE 100.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE 100.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 100.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE 100.0 MILLIVOLTS DC 6TH RADIO INTERFERENCE |
INCLOSURE TYPE | ENCASED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 23 TURRET INPUT 23 TURRET OUTPUT 1 TAB, SOLDER LUG GROUND |
STYLE DESIGNATOR | 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
OVERALL LENGTH | 3.975 INCHES NOMINAL |
BODY LENGTH | 3.000 INCHES NOMINAL |
BODY HEIGHT | 1.547 INCHES NOMINAL |
BODY WIDTH | 5.000 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD 2 THREADED HOLE |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 4.460 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 5915-00-933-5658
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | SG | 403 SCMS/GUED 5215 Thurlow St, Suite 5, Bldg 70C Wright-Patterson AFB OH 45433 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-933-5658
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |