Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-928-3274 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: 0N097192, 0N0971923, 0N097192-3, 5915-00-928-3274, 00-928-3274, 5915009283274, 009283274

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 31 AUG 1966 00-928-3274

Drawings & Photos | NSN 5915-00-928-3274


Cross Reference | NSN 5915-00-928-3274

Part Number Cage Code Manufacturer
0N097192 56289 SPRAGUE ELECTRIC CO WORLD HQS
0N097192 72982 ERIE SPECIALTY PRODUCTS INC
0N097192 96095 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS
0N097192-3 98230 NATIONAL SECURITY AGENCY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-928-3274

Technical Data | NSN 5915-00-928-3274

Characteristic Specifications
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS DC BLANK
OPERATING CURRENT RATING PER FUNCTION IN AMPS 1.5 BLANK
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 TAB, SOLDER LUG INPUT 1 THREADED STUD OUTPUT
STYLE DESIGNATOR 26 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 1.021 INCHES NOMINAL
BODY OUTSIDE DIAMETER 0.406 INCHES NOMINAL
MANUFACTURERS CODE 98230
DESIGN CONTROL REFERENCE 0N097192-3

Restrictions/Controls & Freight Information | NSN 5915-00-928-3274

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XN National Security Agency
ATTN: L111
Fort George G. Meade, MD 20755-6000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-928-3274

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each