Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-762-0578 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: JN331051B, JN33-1051B, RF07339, RF7339, 0N014683, 6B277, 5915-00-762-0578, 00-762-0578, 5915007620578, 007620578

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 31 MAR 1972 00-762-0578

Drawings & Photos | NSN 5915-00-762-0578


Cross Reference | NSN 5915-00-762-0578

Part Number Cage Code Manufacturer
0N014683 98230 NATIONAL SECURITY AGENCY
6B277 13058 SORA POWER INC.
JN33-1051B 56289 SPRAGUE ELECTRIC CO WORLD HQS
RF07339 13619 EMS DEVELOPMENT CORPORATION
RF7339 13619 EMS DEVELOPMENT CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-762-0578

Technical Data | NSN 5915-00-762-0578

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 130.0 VOLTS AC 1ST RADIO INTERFERENCE AND 10.0 VOLTS DC 1ST RADIO INTERFERENCE 130.0 VOLTS AC 2ND RADIO INTERFERENCE AND 10.0 VOLTS DC 2ND RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 440.0 1ST RADIO INTERFERENCE 440.0 2ND RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 0.4 1ST RADIO INTERFERENCE AND 6.0 1ST RADIO INTERFERENCE 0.4 2ND RADIO INTERFERENCE AND 6.0 2ND RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 1.0 VOLTS AC 1ST RADIO INTERFERENCE AND 0.2 VOLTS DC 1ST RADIO INTERFERENCE 1.0 VOLTS AC 2ND RADIO INTERFERENCE AND 0.2 VOLTS DC 2ND RADIO INTERFERENCE
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 2 TAB, SOLDER LUG OUTPUT
STYLE DESIGNATOR 15 RECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES
OVERALL LENGTH 2.085 INCHES NOMINAL
OVERALL HEIGHT 4.175 INCHES NOMINAL
OVERALL WIDTH 2.000 INCHES NOMINAL
BODY LENGTH 1.785 INCHES NOMINAL
BODY WIDTH 2.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.112 INCHES
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
III MAXIMUM TEMP RISE 15.0 DEG CELSIUS
III AVERAGE LIFE RATING IN HOURS 10000.0
III INPUT TERMINAL MANUFACTURER CODE 71468
III INPUT TERMINAL IDENTIFICATION DEDH-9P-202-1
III UNPACKAGED UNIT WEIGHT 19.000 OUNCES
III OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
III BODY MATERIAL METAL

Restrictions/Controls & Freight Information | NSN 5915-00-762-0578

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-762-0578

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each