NSN 5915-00-537-2339 NFT2HR4P1, 713880-053, 0713880053
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-00-537-2339 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: NFT2HR4P1, 713880-053, 0713880053, 0713880-053, 5915-00-537-2339, 00-537-2339, 5915005372339, 005372339, 713880053
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1963 | 00-537-2339 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Cross Reference | NSN 5915-00-537-2339
Part Number | Cage Code | Manufacturer |
---|---|---|
0713880-053 | 05869 | RAYTHEON COMPANY DBA RAYTHEON |
0713880-053 | 82577 | RAYTHEON COMPANY DBA RAYTHEON |
713880-053 | 05869 | RAYTHEON COMPANY DBA RAYTHEON |
713880-053 | 82577 | RAYTHEON COMPANY DBA RAYTHEON |
NFT2HR4P1 | 00853 | CORNELL-DUBILIER MARKETING, INC. |
NFT2HR4P1 | 14655 | CORNELL-DUBILIER ELECTRONICS |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-00-537-2339
Technical Data | NSN 5915-00-537-2339
Characteristic | Specifications |
---|---|
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 150.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 BLANK |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 20.0 BLANK |
INCLOSURE TYPE | HERMETICALLY SEALED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD INPUT 1 THREADED STUD OUTPUT |
STYLE DESIGNATOR | 14 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
OVERALL LENGTH | 1.120 INCHES NOMINAL |
OVERALL HEIGHT | 4.060 INCHES NOMINAL |
OVERALL WIDTH | 1.120 INCHES NOMINAL |
BODY HEIGHT | 0.870 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 0.670 INCHES NOMINAL |
DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END | 2.000 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.155 INCHES MINIMUM AND 0.166 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.875 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.875 INCHES NOMINAL |
III AVERAGE LIFE RATING IN HOURS | 10000.0 |
III OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
III BODY MATERIAL | METAL |
Restrictions/Controls & Freight Information | NSN 5915-00-537-2339
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-537-2339
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |