Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-506-7189 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: 10B5931, 10B593-1, 60914481, 6091448-1, 5915-00-506-7189, 00-506-7189, 5915005067189, 005067189

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 20 JUL 1974 00-506-7189

Drawings & Photos | NSN 5915-00-506-7189


Cross Reference | NSN 5915-00-506-7189

Part Number Cage Code Manufacturer
10B593-1 13058 SORA POWER INC.
6091448-1 03640 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-506-7189

Technical Data | NSN 5915-00-506-7189

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS BLANK
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 200.0 VOLTS AC 1ST RADIO INTERFERENCE 200.0 VOLTS AC 2ND RADIO INTERFERENCE 200.0 VOLTS AC 3RD RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 1ST RADIO INTERFERENCE 400.0 2ND RADIO INTERFERENCE 400.0 3RD RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 1.5 1ST RADIO INTERFERENCE 1.5 2ND RADIO INTERFERENCE 1.5 3RD RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 1.0 VOLTS AC 1ST RADIO INTERFERENCE 1.0 VOLTS AC 2ND RADIO INTERFERENCE 1.0 VOLTS AC 3RD RADIO INTERFERENCE
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 3 TAB, SOLDER LUG INPUT 1 CONNECTOR, RECEPTACLE OUTPUT
STYLE DESIGNATOR 20 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL HEIGHT 4.500 INCHES NOMINAL
BODY LENGTH 5.000 INCHES NOMINAL
BODY HEIGHT 3.000 INCHES NOMINAL
BODY WIDTH 2.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.906 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.112 INCHES
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE INDUCTANCE-CAPACITANCE-RESISTANCE 3RD RADIO INTERFERENCE
III MAXIMUM TEMP RISE 25.0 DEG CELSIUS
III AVERAGE LIFE RATING IN HOURS 50000.0
III OUTPUT TERMINAL MANUFACTURER CODE 81349
III OUTPUT TERMINAL IDENTIFICATION M81511/21ED0151
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 600.0 VOLTS AT SEA LEVEL
III VIBRATION RESISTANCE RANGE IN HERTZ 20.0 TO 500.0
III OPERATING TEMP RANGE -54.0 TO 85.0 DEG CELSIUS
III BODY MATERIAL METAL

Restrictions/Controls & Freight Information | NSN 5915-00-506-7189

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-506-7189

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each