Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-503-9797 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: JAN141539A, JAN14-1539A, JN141539A, JN14-1539A, 220238-001, 220238-002, 220238002VM, 220238-002VM, 4504305, 450430-5, 5915-00-503-9797, 00-503-9797, 5915005039797, 220238001, 220238002, 005039797

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 13 JUL 1974 00-503-9797

Drawings & Photos | NSN 5915-00-503-9797


Demand History | NSN 5915-00-503-9797

Part Number Request Date QTY Origin
220238-001 2024-03-88 26 DIBBS
450430-5 2024-03-88 26 DIBBS
JN14-1539A 2024-03-88 26 DIBBS
220238-001 2023-12-341 6 DIBBS
450430-5 2023-12-341 6 DIBBS
JN14-1539A 2023-12-341 6 DIBBS
220238-001 2023-09-271 5 DIBBS
450430-5 2023-09-271 5 DIBBS
JN14-1539A 2023-09-271 5 DIBBS
220238-001 2023-09-257 6 DIBBS
450430-5 2023-09-257 6 DIBBS
JN14-1539A 2023-09-257 6 DIBBS
220238-001 2023-08-229 23 DIBBS
450430-5 2023-08-229 23 DIBBS
JN14-1539A 2023-08-229 23 DIBBS
220238-001 2023-05-145 4 DIBBS
450430-5 2023-05-145 4 DIBBS
JN14-1539A 2023-05-145 4 DIBBS
220238-001 2023-02-47 5 DIBBS
450430-5 2023-02-47 5 DIBBS
JN14-1539A 2023-02-47 5 DIBBS
220238-001 2022-10-286 2 DIBBS
450430-5 2022-10-286 2 DIBBS
JN14-1539A 2022-10-286 2 DIBBS
220238-001 2022-06-173 6 DIBBS
450430-5 2022-06-173 6 DIBBS
JN14-1539A 2022-06-173 6 DIBBS
220238-001 2022-06-171 5 DIBBS
450430-5 2022-06-171 5 DIBBS
JN14-1539A 2022-06-171 5 DIBBS
220238-001 2022-05-138 10 DIBBS
450430-5 2022-05-138 10 DIBBS
JN14-1539A 2022-05-138 10 DIBBS
220238-001 2022-05-121 10 DIBBS
450430-5 2022-05-121 10 DIBBS
JN14-1539A 2022-05-121 10 DIBBS
220238-001 2021-04-109 10 DIBBS
450430-5 2021-04-109 10 DIBBS
JN14-1539A 2021-04-109 10 DIBBS
220238-001 2021-04-94 10 DIBBS
450430-5 2021-04-94 10 DIBBS
JN14-1539A 2021-04-94 10 DIBBS
220238-001 2020-05-139 19 DIBBS
450430-5 2020-05-139 19 DIBBS
JN14-1539A 2020-05-139 19 DIBBS
220238-001 2020-05-128 19 DIBBS
450430-5 2020-05-128 19 DIBBS
JN14-1539A 2020-05-128 19 DIBBS
5915-00-503-9797 2017-05-138 20 DIBBS
5915-00-503-9797 2017-05-127 20 DIBBS
5915-00-503-9797 2015-12-343 18 DIBBS
5915-00-503-9797 2015-01-11 18 DIBBS
5915-00-503-9797 2013-01-31 15 DIBBS
5915-00-503-9797 2010-08-231 10 DIBBS
5915-00-503-9797 2010-07-183 15 DIBBS
5915-00-503-9797 2008-09-248 11 DIBBS
5915-00-503-9797 2008-08-232 4 DIBBS
5915-00-503-9797 2006-06-167 18 DIBBS
5915-00-503-9797 2006-06-164 0 DIBBS

Cross Reference | NSN 5915-00-503-9797

Part Number Cage Code Manufacturer
220238-001 56289 SPRAGUE ELECTRIC CO WORLD HQS
220238-001 95802 AIR SYSTEM COMPONENTS, INC DBA TRION IAQ DIV
220238-002 95802 AIR SYSTEM COMPONENTS, INC DBA TRION IAQ DIV
220238-002VM 03950 NAVAL INVENTORY CONTROL POINT MECHANICSBURG
450430-5 95802 AIR SYSTEM COMPONENTS, INC DBA TRION IAQ DIV
JAN14-1539A 56289 SPRAGUE ELECTRIC CO WORLD HQS
JN14-1539A 13619 EMS DEVELOPMENT CORPORATION
JN14-1539A 56289 SPRAGUE ELECTRIC CO WORLD HQS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-503-9797

Technical Data | NSN 5915-00-503-9797

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 120.0 VOLTS AC 1ST RADIO INTERFERENCE AND 120.0 VOLTS DC 1ST RADIO INTERFERENCE 120.0 VOLTS AC 2ND RADIO INTERFERENCE AND 120.0 VOLTS AC 2ND RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 1ST RADIO INTERFERENCE 60.0 2ND RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 1ST RADIO INTERFERENCE 5.0 2ND RADIO INTERFERENCE
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG INPUT 2 TAB, SOLDER LUG OUTPUT
STYLE DESIGNATOR 30 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 4.000 INCHES NOMINAL
OVERALL HEIGHT 2.125 INCHES NOMINAL
BODY LENGTH 3.062 INCHES NOMINAL
BODY WIDTH 2.875 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 8 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.195 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 3.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 2.125 INCHES NOMINAL
III OPERATING TEMP RANGE -55.0 TO 85.0 DEG CELSIUS
III BODY MATERIAL METAL

Restrictions/Controls & Freight Information | NSN 5915-00-503-9797

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-503-9797

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each