NSN 5915-00-386-8335 RF01993, RF1993, 145377
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-00-386-8335 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: RF01993, RF1993, 145377, 5915-00-386-8335, 00-386-8335, 5915003868335, 003868335
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 25 MAR 1974 | 00-386-8335 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Demand History | NSN 5915-00-386-8335
Part Number | Request Date | QTY | Origin |
---|---|---|---|
145377 | 2019-12-338 | 4 | DIBBS |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-00-386-8335
Technical Data | NSN 5915-00-386-8335
Characteristic | Specifications |
---|---|
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 400.0 VOLTS AC BLANK AND 130.0 VOLTS DC BLANK |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 BLANK |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 BLANK |
MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS DC BLANK |
INCLOSURE TYPE | HERMETICALLY SEALED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG INPUT 1 TAB, SOLDER LUG OUTPUT |
STYLE DESIGNATOR | 9 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
OVERALL LENGTH | 5.063 INCHES NOMINAL |
BODY LENGTH | 3.938 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 1.500 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNEF |
NOMINAL THREAD SIZE | 0.625 INCHES |
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
III VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
III OPERATING TEMP RANGE | -65.0 TO 85.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 5915-00-386-8335
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-386-8335
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |