Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-376-9010 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: FA744, 20037, 5915-00-376-9010, 00-376-9010, 5915003769010, 003769010

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-376-9010

Drawings & Photos | NSN 5915-00-376-9010


Cross Reference | NSN 5915-00-376-9010

Part Number Cage Code Manufacturer
20037 04598 THE AUSTIN COMPANY
FA744 13619 EMS DEVELOPMENT CORPORATION
FA744 81831 FILTRON CO INC DIV OF RFI CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-376-9010

Technical Data | NSN 5915-00-376-9010

Characteristic Specifications
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 BLANK
OPERATING CURRENT RATING PER FUNCTION IN AMPS 8.0 BLANK
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG INPUT 2 TAB, SOLDER LUG OUTPUT
STYLE DESIGNATOR 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 3.875 INCHES NOMINAL
BODY LENGTH 2.562 INCHES NOMINAL
BODY HEIGHT 2.000 INCHES NOMINAL
BODY WIDTH 2.812 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 1 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.203 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 3.375 INCHES NOMINAL
MANUFACTURERS CODE 04598
DESIGN CONTROL REFERENCE 20037

Restrictions/Controls & Freight Information | NSN 5915-00-376-9010

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeYInformation is in the Hazardous Materials Information System (HMIS)
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Hazardous Control Code:Z3Article Containing Polychlorinated Biphenyl (PCB) ARTICLE, PCB
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-376-9010

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each