Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-376-8945 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: N36310561ISSUE2, N363-1056-1ISSUE2, S36310561, S363-1056-1, S36310561ISSUE2, S363-1056-1ISSUE2, FA376, 3631056P1, 363-1056P1, 5915-00-376-8945, 00-376-8945, 5915003768945, 003768945

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-376-8945

Drawings & Photos | NSN 5915-00-376-8945


Cross Reference | NSN 5915-00-376-8945

Part Number Cage Code Manufacturer
363-1056P1 49956 RAYTHEON COMPANY DBA RAYTHEON
FA376 13619 EMS DEVELOPMENT CORPORATION
FA376 81831 FILTRON CO INC DIV OF RFI CORP
N363-1056-1ISSUE2 49956 RAYTHEON COMPANY DBA RAYTHEON
S363-1056-1 49956 RAYTHEON COMPANY DBA RAYTHEON
S363-1056-1ISSUE2 49956 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-376-8945

Technical Data | NSN 5915-00-376-8945

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS BLANK
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 130.0 VOLTS AC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 BLANK
OPERATING CURRENT RATING PER FUNCTION IN AMPS 27.0 BLANK
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 THREADED STUD INPUT 1 THREADED STUD OUTPUT
STYLE DESIGNATOR 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 3.124 INCHES MAXIMUM
BODY LENGTH 2.000 INCHES MINIMUM AND 2.031 INCHES MAXIMUM
BODY HEIGHT 2.062 INCHES MAXIMUM
BODY WIDTH 0.781 INCHES MINIMUM AND 1.219 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.359 INCHES MINIMUM AND 2.391 INCHES MAXIMUM
III MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE 130.0 VOLTS AT SEA LEVEL
III OPERATING TEMP RANGE -54.0 TO 75.0 DEG CELSIUS
MANUFACTURERS CODE 49956
DESIGN CONTROL REFERENCE S363-1056-1

Restrictions/Controls & Freight Information | NSN 5915-00-376-8945

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeYInformation is in the Hazardous Materials Information System (HMIS)
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Hazardous Control Code:Z3Article Containing Polychlorinated Biphenyl (PCB) ARTICLE, PCB
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-376-8945

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityAItem requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each