Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-275-2142 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: 2301652, 230165-2, 3901782, 390178-2, 5915-00-275-2142, 00-275-2142, 5915002752142, 002752142

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 04 AUG 1973 00-275-2142

Drawings & Photos | NSN 5915-00-275-2142


Cross Reference | NSN 5915-00-275-2142

Part Number Cage Code Manufacturer
230165-2 00752 EDO CORPORATION DIV EDO CORPORATION AP&T
390178-2 05869 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-275-2142

Technical Data | NSN 5915-00-275-2142

Characteristic Specifications
INPUT IMPEDANCE PER FUNCTION W/LOAD 50.0 OHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT 50.0 OHMS BLANK
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 28.0 VOLTS DC BLANK
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 1 CONNECTOR, RECEPTACLE OUTPUT
STYLE DESIGNATOR 12 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 1.880 INCHES NOMINAL
OVERALL HEIGHT 0.500 INCHES NOMINAL
BODY LENGTH 1.125 INCHES NOMINAL
BODY WIDTH 0.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 TERMINAL
III AVERAGE LIFE RATING IN HOURS 43800.0
III INPUT TERMINAL MANUFACTURER CODE 80058
III INPUT TERMINAL IDENTIFICATION UG-1619/U
III OUTPUT TERMINAL MANUFACTURER CODE 16179
III OUTPUT TERMINAL IDENTIFICATION TYPE-OSM
III OPERATING TEMP RANGE 0.0 TO 50.0 DEG CELSIUS
III BODY MATERIAL METAL
MANUFACTURERS CODE 05869
DESIGN CONTROL REFERENCE 390178-2

Restrictions/Controls & Freight Information | NSN 5915-00-275-2142

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code HH Navy ICP
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-275-2142

Category Code Description
Cognizance Codes3BNavy-owned stocks of field level repairable DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityDField Level Reparables
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each