NSN 5915-00-156-7834 FA4945, 6166, 1192
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-00-156-7834 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: FA4945, 6166, 1192, 5360, 5915-00-156-7834, 00-156-7834, 5915001567834, 001567834
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1963 | 00-156-7834 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Cross Reference | NSN 5915-00-156-7834
Part Number | Cage Code | Manufacturer |
---|---|---|
1192 | 00853 | CORNELL-DUBILIER MARKETING, INC. |
1192 | 14655 | CORNELL-DUBILIER ELECTRONICS |
5360 | 00853 | CORNELL-DUBILIER MARKETING, INC. |
5360 | 14655 | CORNELL-DUBILIER ELECTRONICS |
6166 | 00853 | CORNELL-DUBILIER MARKETING, INC. |
6166 | 14655 | CORNELL-DUBILIER ELECTRONICS |
FA4945 | 13619 | EMS DEVELOPMENT CORPORATION |
FA4945 | 81831 | FILTRON CO INC DIV OF RFI CORP |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-00-156-7834
Technical Data | NSN 5915-00-156-7834
Characteristic | Specifications |
---|---|
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 150.0 VOLTS AC BLANK AND 150.0 VOLTS DC BLANK |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.25 BLANK |
INCLOSURE TYPE | ENCASED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG INPUT 2 TAB, SOLDER LUG OUTPUT |
OVERALL LENGTH | 3.172 INCHES MINIMUM AND 3.204 INCHES MAXIMUM |
BODY LENGTH | 2.109 INCHES MINIMUM AND 2.141 INCHES MAXIMUM |
BODY HEIGHT | 1.750 INCHES MAXIMUM |
BODY WIDTH | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.672 INCHES MINIMUM AND 2.704 INCHES MAXIMUM |
MANUFACTURERS CODE | 14655 |
DESIGN CONTROL REFERENCE | 1192 |
Restrictions/Controls & Freight Information | NSN 5915-00-156-7834
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | Y | Information is in the Hazardous Materials Information System (HMIS) |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Hazardous Control Code: | Z3 | Article Containing Polychlorinated Biphenyl (PCB) ARTICLE, PCB |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-156-7834
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |