NSN 5910-01-135-0969 DV2SN60Q, 01-135-0969, 011350969
Product Details | CERAMIC DIELECTRIC VARIABLE CAPACITOR
5910-01-135-0969 A capacitor whose capacitance value is controlled by a mechanical means which effects a continuous variation of its capacitance. It includes items consisting of two or more variable capacitors which are inseparable.
Part Alternates: DV2SN60Q, 5910-01-135-0969, 01-135-0969, 5910011350969, 011350969
Electrical and Electronic Equipment Components | Capacitors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 18 JUL 1982 | 01-135-0969 | 00721 ( CAPACITOR, VARIABLE, CERAMIC DIELECTRIC ) |
Cross Reference | NSN 5910-01-135-0969
Part Number | Cage Code | Manufacturer |
---|---|---|
DV2SN60Q | 51406 | MURATA ERIE NORTH AMERICA INC HEADQUARTERS AND GEORGIA OPNS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5910-01-135-0969
Related Products | NSN 5910-01-135-0969
Technical Data | NSN 5910-01-135-0969
Characteristic | Specifications |
---|---|
CAPACITANCE RANGE IN PICOFARADS | 10.0 TO 60.0 SINGLE SECTION |
NONDERATED VOLTAGE RATING AND TYPE | 100.0 DC CONTINUOUS SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
TEMP COEFFICIENT OF CAPACITANCE IN PPM PER DEG CELSIUS | -1200.0 SINGLE SECTION |
TOLERANCE OF TEMP COEFFICIENT IN PPM PER DEG CELSIUS | -500.0 TO 500.0 SINGLE SECTION |
BODY STYLE | 47 ROTARY |
BODY LENGTH | 0.236 INCHES NOMINAL |
BODY WIDTH | 0.236 INCHES NOMINAL |
BODY HEIGHT | 0.189 INCHES NOMINAL |
INCLOSURE TYPE | ENCASED |
ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY | 1 SLOTTED SCREW |
ADJUSTMENT DEVICE TORQUE | 0.400 INCH-OUNCES MINIMUM AND 2.800 INCH-OUNCES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 2 PRINTED CIRCUIT |
TERMINAL LENGTH | 0.128 INCHES NOMINAL |
TERMINAL WIDTH | 0.039 INCHES NOMINAL |
TERMINAL THICKNESS | 0.010 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.197 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
III INSULATION DC RESISTANCE AT 25 DEG CELSIUS | 100000.0 MEGOHMS |
Restrictions/Controls & Freight Information | NSN 5910-01-135-0969
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5910-01-135-0969
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |