Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-850-6183 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: CL45CB300SP3, MILC3965, 5910-00-850-6183, 00-850-6183, 5910008506183, 008506183

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1962 00-850-6183

Drawings & Photos | NSN 5910-00-850-6183


Cross Reference | NSN 5910-00-850-6183

Part Number Cage Code Manufacturer
CL45CB300SP3 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MILC3965 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-850-6183

Technical Data | NSN 5910-00-850-6183

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 30.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -15.00 TO 30.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 6.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.312 INCHES MAXIMUM
BODY LENGTH 0.484 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES NOMINAL
CASE MATERIAL METAL
CAPACITIVE ELECTRODE MATERIAL TANTALUM
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS 4.00
DC LEAKAGE AT REFERENCE TEMP 1.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
FEATURES PROVIDED HERMETICALLY SEALED CASE
TEST DATA DOCUMENT 81349-MIL-C-3965 SPECIFICATION
III TERMINAL SURFACE TREATMENT SOLDER
III ANODE TYPE SOLID
III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 100.0
(NON-CORE DATA) OVERALL LENGTH 0.484 INCHES NOMINAL
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 2.0 MILLIAMPERES
(NON-CORE DATA) OVERALL HEIGHT 0.312 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 0.312 INCHES MAXIMUM
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE CL45CB300SP3
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MILC3965

Restrictions/Controls & Freight Information | NSN 5910-00-850-6183

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-850-6183

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each