Product Details | NONPRECISION NONWIRE WOUND VARIABLE RESISTOR

5905-01-081-3666 A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.

Part Alternates: 18054, 18-054, 3099P1204, 3099P-1-204, 5905-01-081-3666, 01-081-3666, 5905010813666, 010813666

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 12 AUG 1979 01-081-3666

Drawings & Photos | NSN 5905-01-081-3666


Cross Reference | NSN 5905-01-081-3666

Part Number Cage Code Manufacturer
18-054 00816 PALOMAR PRODUCTS, INC.
3099P-1-204 32997 BOURNS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-081-3666

Technical Data | NSN 5905-01-081-3666

Characteristic Specifications
SECTION QUANTITY 1
ELECTRICAL RESISTANCE PER SECTION 200.0 KILOHMS SINGLE SECTION
RESISTANCE TOLERANCE PER SECTION IN PERCENT -10.0 TO 10.0 SINGLE SECTION
STANDARD TAPER CURVE PER SECTION A SINGLE SECTION
SHAFT BEARING TYPE BEARING
MAXIMUM STARTING TORQUE 5.00 INCH-OUNCES
MAXIMUM RUNNING TORQUE 5.00 INCH-OUNCES
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS -100.0 TO 100.0 SINGLE SECTION
POWER DISSIPATION RATING PER SECTION IN WATTS 1.0 FREE AIR SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER 70.0 SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER 150.0 SINGLE SECTION
BODY STYLE 45B RECTANGULAR
BODY LENGTH 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
BODY WIDTH 0.245 INCHES MINIMUM AND 0.255 INCHES MAXIMUM
BODY HEIGHT 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM
ACTUATOR TYPE FLUSH DRIVE WITH SLOT-HOLE
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG 7200.0 NOMINAL
ACTUATOR TRAVEL CONTROL FEATURE CLUTCH
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION 7200.0 NOMINAL
MOUNTING METHOD TERMINAL
FEATURES PROVIDED HUMIDITY PROOF
TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG
TERMINAL LOCATION LOWER ADJACENT SIDE TWO ROWS
RELIABILITY INDICATOR NOT ESTABLISHED
III UNPACKAGED UNIT WEIGHT 2.8 GRAMS
III CUBIC MEASURE 0.038 CUBIC INCHES
III FRAGILITY FACTOR MODERATELY RUGGED

Restrictions/Controls & Freight Information | NSN 5905-01-081-3666

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5905-01-081-3666

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each