Product Details | INDUCTIVE WIRE WOUND FIXED RESISTOR

5905-00-272-7329 INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.

Part Alternates: MILR15109A, 1 3-4Z219TVIT3500HM, 134Z219TVIT3500HM, 2595163, 25951-6-3, 4352, 435-2, 5905-00-272-7329, 00-272-7329, 5905002727329, 002727329

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-272-7329

Drawings & Photos | NSN 5905-00-272-7329


Cross Reference | NSN 5905-00-272-7329

Part Number Cage Code Manufacturer
1 3-4Z219TVIT3500HM 63743 WARD LEONARD ELECTRIC COMPANY INC.
25951-6-3 63743 WARD LEONARD ELECTRIC COMPANY INC.
435-2 07860 BOGUE ELECTRIC MANUFACTURING CO
435-2 0BXF1 BOGUE SYSTEMS INC.
MILR15109A 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-272-7329

Technical Data | NSN 5905-00-272-7329

Characteristic Specifications
ELECTRICAL RESISTANCE 350.000 OHMS
RESISTANCE TOLERANCE IN PERCENT -10.000 TO 10.000
POWER DISSIPATION RATING IN WATTS 10.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 50.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 350.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 20 RADIAL TERMINAL EACH END
BODY DIAMETER 0.312 INCHES NOMINAL
BODY LENGTH 1.750 INCHES NOMINAL
TERMINAL TYPE TAB, SOLDER LUG
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 0.562 INCHES NOMINAL
TERMINAL WIDTH 0.250 INCHES NOMINAL
TEST DATA DOCUMENT 81349-MILR15109B SPECIFICATION
NONDEFINITIVE SPEC/STD DATA IW FORM
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MILR15109A

Restrictions/Controls & Freight Information | NSN 5905-00-272-7329

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-00-272-7329

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each