Product Details | TURNBUCKLE

5340-01-483-2107 A metal loop, sleeve, or solid body with end pulls, having both ends threaded or one end threaded and the other end designed to accommodate a swivel. Items with both ends threaded shall have right hand screw threads on one end and left hand screw threads on the other. It may include lock nuts, check nuts, jam nuts, and/or terminal attachment(s) such as hooks, rings, and the like. It is designed to regulate the distance (take-up) between two points by turning. See also PELICAN HOOK AND TURNBUCKLE ASSEMBLY; and TIE ROD, TENSIONING, THREADED END.

Part Alternates: HG228-3/4X18IN, HG22834X18IN, 5340-01-483-2107, 01-483-2107, 5340014832107, 014832107

Hardware and Abrasives | Hardware, Commercial

Supply Group (FSG) NSN Assign. NIIN
53 20 MAR 2001 01-483-2107

Drawings & Photos | NSN 5340-01-483-2107


Cross Reference | NSN 5340-01-483-2107

Part Number Cage Code Manufacturer
HG228-3/4X18IN 75535 CROSBY GROUP INC DBA NATIONAL SWAGE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5340-01-483-2107

Technical Data | NSN 5340-01-483-2107

Characteristic Specifications
MATERIAL STEEL OVERALL
THREAD SERIES DESIGNATOR UN BODY
NOMINAL THREAD SIZE 0.750 INCHES BODY
THREAD QUANTITY PER INCH 12 BODY
THREAD DIRECTION RIGHT-HAND BODY
END STYLE 200 CLEVIS AND CLEVIS
FORK WIDTH 19.1 MILLIMETERS NOMINAL
TAKE-UP DISTANCE 305.0 MILLIMETERS NOMINAL
SPECIAL FEATURES HOT DIPPED GALVANIZED STEEL; END FITTINGS QUENCHED AND TEMPERED; BODIES HEAT TREATED BY NORMALIZING; FATIGUE RATED

Restrictions/Controls & Freight Information | NSN 5340-01-483-2107

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information