Product Details | SPECTRUM ANALYZER

6625-01-622-9319 An instrument specifically designed to measure the amplitude and frequency of the constituents of a complex electrical wave form. May include transducer mechanism for converting sound pressure into electrical energy.

Part Alternates: RSA2150BSBS, RSA-2150B-SBS , 6625-01-622-9319, 01-622-9319, 6625016229319, 016229319

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 2013298 01-622-9319

Cross Reference | NSN 6625-01-622-9319

Part Number Cage Code Manufacturer
RSA-2150B-SBS 0M0K6 AVCOM OF VIRGINIA, INC. DBA AVCOM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-622-9319

Technical Data | NSN 6625-01-622-9319

Characteristic Specifications
UNIT TYPE PLUG-IN
FREQUENCY RANGE RATING -950.0 TO 2150.0 MEGAHERTZ
PLUG-IN UNIT QUANTITY 1
OVERALL LENGTH 7.0 INCHES NOMINAL
OVERALL WIDTH 5.0 INCHES NOMINAL
OVERALL HEIGHT 1.5 INCHES NOMINAL
SPECIAL FEATURES MIL-STD 810F APPROVED; SPAN WIDTH 0-1300 MHZ; RESOLUTION BANDWIDTH 10KHZ, 100KHZ, 300KHZ, 1MHZ;REFERENCE LEVELS-SELECTABLE 10 DBM TO 50 DBM IN 1 OR 5 DB STEPS; SCALE 5DB/DIV AND 2 DB/DIV; DYNAMIC RANGE 40 DB ON APPLICATION WINDOW; 2 POUNDS; +5 TO 24 VDC/9W
PART NAME ASSIGNED BY CONTROLLING AGENCY SINGLE BOARD EMBEDDED SPECTRUM ANALYZER

Restrictions/Controls & Freight Information | NSN 6625-01-622-9319

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information