NSN 6625-01-531-5727 RSA3303A0221, RSA3303A-02-21, 01-531-5727
Product Details | SPECTRUM ANALYZER
6625-01-531-5727 An instrument specifically designed to measure the amplitude and frequency of the constituents of a complex electrical wave form. May include transducer mechanism for converting sound pressure into electrical energy.
Part Alternates: RSA3303A0221, RSA3303A-02-21, 6625-01-531-5727, 01-531-5727, 6625015315727, 015315727
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 14 JUL 2005 | 01-531-5727 | 00833 ( ANALYZER, SPECTRUM ) |
Cross Reference | NSN 6625-01-531-5727
Part Number | Cage Code | Manufacturer |
---|---|---|
RSA3303A-02-21 | 80009 | TEKTRONIX, INC. DBA TEKTRONIX |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-531-5727
Related Products | NSN 6625-01-531-5727
Technical Data | NSN 6625-01-531-5727
Characteristic | Specifications |
---|---|
UNIT TYPE | STANDARD |
AC VOLTAGE RATING | 100.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM |
OVERALL WIDTH | 425.0 MILLIMETERS NOMINAL |
OVERALL HEIGHT | 215.0 MILLIMETERS NOMINAL |
OVERALL DEPTH | 425.0 MILLIMETERS NOMINAL |
MOUNTING METHOD | RACK |
SPECIAL FEATURES | OPTION 02 256 MB DATA MEMORY WITH FREQUENCY MASK TRIGGER, OPTION 21 GENERAL PURPOSE DIGITAL MODULATION ANALYSIS; FREQUENCY RANGE DC TO 3GHZ; 15MHZ REAL-TIME CAPTURE BANDWIDTH |
Restrictions/Controls & Freight Information | NSN 6625-01-531-5727
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |