Product Details | SPECTRUM ANALYZER

6625-01-503-6453 An instrument specifically designed to measure the amplitude and frequency of the constituents of a complex electrical wave form. May include transducer mechanism for converting sound pressure into electrical energy.

Part Alternates: 8903B/010/011, 8903B010011, 6625-01-503-6453, 01-503-6453, 6625015036453, 015036453

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 2003 01-503-6453

Cross Reference | NSN 6625-01-503-6453

Part Number Cage Code Manufacturer
8903B/010/011 1LQK8 KEYSIGHT TECHNOLOGIES, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-503-6453

Technical Data | NSN 6625-01-503-6453

Characteristic Specifications
FREQUENCY RANGE RATING 0.005 TO 100.000 KILOHERTZ
INDIVIDUAL PLUG-IN UNIT FREQUENCY 20.0 HERTZ AND 100.0 KILOHERTZ
AC VOLTAGE RATING 0.3 MILLIVOLTS MINIMUM AND 300.0 VOLTS MAXIMUM
DC VOLTAGE RATING 4.0 VOLTS MINIMUM AND 300.0 VOLTS MAXIMUM
OVERALL WIDTH 16.800 INCHES NOMINAL
OVERALL HEIGHT 5.750 INCHES NOMINAL
OVERALL DEPTH 18.200 INCHES NOMINAL
MOUNTING METHOD RACK
RECORDING DEVICE ACCOMMODATION NOT PROVIDED
SPECIAL FEATURES OPT 010 IS 400 HERTZ HIGH-PASS FILTER ON THE LEFT SIDE; OPT 011 IS CCITT WEIGHTING FILTER ON THE LEFT SIDE
III UNPACKAGED UNIT WEIGHT 27.000 POUNDS

Restrictions/Controls & Freight Information | NSN 6625-01-503-6453

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information