Product Details | SPECTRUM ANALYZER

6625-01-306-8046 An instrument specifically designed to measure the amplitude and frequency of the constituents of a complex electrical wave form. May include transducer mechanism for converting sound pressure into electrical energy.

Part Alternates: 35660A001908, 35660A-001-908, 6625-01-306-8046, 01-306-8046, 6625013068046, 013068046

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 30 AUG 1989 01-306-8046

Cross Reference | NSN 6625-01-306-8046

Part Number Cage Code Manufacturer
35660A-001-908 1LQK8 KEYSIGHT TECHNOLOGIES, INC.
35660A-001-908 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-306-8046

Technical Data | NSN 6625-01-306-8046

Characteristic Specifications
FREQUENCY RANGE RATING 0.000 TO 102.400 KILOHERTZ
INDIVIDUAL PLUG-IN UNIT FREQUENCY NOT RATED
INPUT IMPEDANCE RATING 1.0 MEGOHMS NOMINAL
AC VOLTAGE RATING 90.0 VOLTS MINIMUM AND 264.0 VOLTS MAXIMUM
FREQUENCY RATING 48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM
OVERALL LENGTH 21.190 INCHES NOMINAL
OVERALL WIDTH 16.750 INCHES NOMINAL
OVERALL HEIGHT 8.750 INCHES NOMINAL
MOUNTING METHOD RACK
RECORDING DEVICE ACCOMMODATION PROVIDED
RECORDING DEVICE TYPE X-Y RECORDER
SPECIAL FEATURES BUILT-IN 3.5 IN. DISC DRIVE; TESTS FOR DISTORTION,SPUR LEVEL,FREQ DRIFT,INTERMODULATION; BUILT-IN SOURCE; ANLDA2
III UNPACKAGED UNIT WEIGHT 47.000 POUNDS
MANUFACTURERS CODE 1LQK8
DESIGN CONTROL REFERENCE 35660A-001-908

Restrictions/Controls & Freight Information | NSN 6625-01-306-8046

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-01-306-8046

Category Code Description
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1