Product Details | FAULT LOCATING INDICATOR

6625-01-305-7018 An electrically activated item specifically designed to indicate the occurrence of a malfunction in a component of an electronic set, central or system. It may indicate the malfunction by a pop-out button (e.g. ground fault interrupt outlets) or color change by emitted light or displayed in a window. The indicator may utilize a "push to test" button. It does not make quantitative or qualitative tests such a provided by test sets.

Part Alternates: BHGD37T28R/BLK, BHGD37T28RBLK, 6625-01-305-7018, 01-305-7018, 6625013057018, 013057018

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 10 AUG 1989 01-305-7018

Demand History | NSN 6625-01-305-7018

Part Number Request Date QTY Origin
6625-01-305-7018 2022-11-321 1 US
6625-01-305-7018 2022-09-249 1 AR
6625-01-305-7018 2022-09-247 1 AR

Cross Reference | NSN 6625-01-305-7018

Part Number Cage Code Manufacturer
BHGD37T28R/BLK 07479 MINELCO INC SUB OF TALLEY INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-305-7018

Technical Data | NSN 6625-01-305-7018

Characteristic Specifications
CASE MATERIAL ALUMINUM
PRESENTATION TYPE DROP FLAGS
COLOR RED MARKER OVERALL
CURRENT TYPE DC
DC VOLTAGE RATING 28.0 VOLTS NOMINAL
COIL DC RESISTANCE 1000000.0 OHMS NOMINAL
CONTACT QUANTITY 4
CONTACT TYPE SOLDER LUG
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED CASE
LENGTH 1.260 INCHES MINIMUM AND 1.320 INCHES MAXIMUM
DIAMETER 0.470 INCHES MINIMUM AND 0.530 INCHES MAXIMUM
FEATURES PROVIDED COIL AND HERMETICALLY SEALED CASE AND WATERPROOF
SPECIAL FEATURES MAGNETIC LATCHING; THREADED BODY MOUNTING PROVISION; SEALED GLASS WINDOW
III FSC APPLICATION DATA TEST SET,ELECT. EQUIP.

Restrictions/Controls & Freight Information | NSN 6625-01-305-7018

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information