NSN 6625-01-284-5163 28357141, 2835714-1, 01-284-5163
Product Details | SPECTRUM ANALYZER
6625-01-284-5163 An instrument specifically designed to measure the amplitude and frequency of the constituents of a complex electrical wave form. May include transducer mechanism for converting sound pressure into electrical energy.
Part Alternates: 28357141, 2835714-1, 6625-01-284-5163, 01-284-5163, 6625012845163, 012845163
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 25 AUG 1988 | 01-284-5163 | 00833 ( ANALYZER, SPECTRUM ) |
Cross Reference | NSN 6625-01-284-5163
Part Number | Cage Code | Manufacturer |
---|---|---|
2835714-1 | 52088 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-284-5163
Related Products | NSN 6625-01-284-5163
Technical Data | NSN 6625-01-284-5163
Characteristic | Specifications |
---|---|
PLUG-IN UNIT QUANTITY | 6 |
MOUNTING METHOD | CABINET |
III END ITEM IDENTIFICATION | P-3 ACFT |
III FSC APPLICATION DATA | SIGNAL PROCESSER,AN/UYS-1 (V) |
MANUFACTURERS CODE | 52088 |
DESIGN CONTROL REFERENCE | 2835714-1 |
Restrictions/Controls & Freight Information | NSN 6625-01-284-5163
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | M | 85 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-01-284-5163
Category | Code | Description |
---|---|---|
Cognizance Codes | 7R | Aeronautical Depot Level Repairable Spares Naval Inventory Control Point, Philadelphia |
Special Material ID | UY | Advanced signal processor (AN/UYS-1) |
Issue Repair, or Requisition | AR | Repairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved. |
Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
Source of Supply | N32 | Naval Inventory Control Point Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | H | Depot Level Reparable |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |