Product Details | RADIO FREQUENCY POWER DIVIDER

6625-01-237-0342 An item specifically designed to separate incoming radio frequency power into predetermined proportional values at its output terminals.20358950037Miscellaneous Communication Equipment59850043Antennas, Waveguides, and Related Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: HP11667B, 11667B, 4144642, 414-4642 , 6625-01-237-0342, 01-237-0342, 6625012370342, 012370342

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 24 JUL 1986 01-237-0342

Demand History | NSN 6625-01-237-0342

Part Number Request Date QTY Origin
6625-01-237-0342 2012-10-283 1 US
11667B 2011-08-237 1
6625-01-237-0342 2011-02-39 1 IN

Cross Reference | NSN 6625-01-237-0342

Part Number Cage Code Manufacturer
11667B 1LQK8 KEYSIGHT TECHNOLOGIES, INC.
11667B 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP
11667B KA563 KEYSIGHT TECHNOLOGIES UK LIMITED
HP11667B K3464 HEWLETT-PACKARD LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-237-0342

Technical Data | NSN 6625-01-237-0342

Characteristic Specifications
SPECIAL FEATURES FREQUENCY RANGE DC TO 26.5GHZ; IMPEDANCE 50 OHMS NOMINAL; INSERTION LOSS 6 DB NOMINAL; INPUT SWR DC TO 18GHZ PLUS/MINUS 1.22,DC TO 26.5 PLUS/MINUS 1.29; OUTPUT SWR DC TO 26.5GHZ PLUS/MINUS 1.22; OUTPUT TRACKING DC TO 18GHZ PLUS/MINUS 0.20 DB,DC TO 26.5GHZ PLUS/MINUS 0.25 DB; PHASE TRACKING DC TO 18GHZ 1.5DEG,DC TO 26.5GHZ 2.5DEG; MAX INPUT PWR PLUS 27DB; CONNECTORS/TYPE 3 APC-3.5 FEMALE; 40.0MM H BY 47.0MM W BY 10MM D; 0.06KG

Restrictions/Controls & Freight Information | NSN 6625-01-237-0342

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-01-237-0342

Category Code Description
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesLLOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management Code4Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665
Echelon Management Code1ICP All Marine Corps-managed items which have not been assigned to integrated materiel management and which are centrally managed by the inventory control point on a system-wide basis.
Operational Test Code3All items requiring calibration. Items may be technical or non-technical in nature, (i.e., electronic test equipment, meters, gauges, torque wrenches, etc.) All OTC 3 items require established calibration procedures.BLANK
Source of SupplyMPBCommanding General
Marine Corps Logistics Command
566-2, Bldg. 3700
Albany, GA 31704-5000
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes1RAeronautical, photographic, and meteorological material (consumable or expense type material)
Naval Inventory Control Point, Philadelphia
Special Material IDA9Consolidated Automated Support System (CASS). USM-636 Electrical Equipment Test System.
Source of SupplyN32Naval Inventory Control Point
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityWGround Support Equipment-End Items
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each