Product Details | RADIO TEST SET

6625-01-182-0106 A test set primarily designed for use in making examinations of radio equipment. See also TEST SET, ELECTRON TUBE; MULTIMETER; OSCILLOSCOPE; GENERATOR, SIGNAL; and TEST SET, AMPLIFIER.

Part Alternates: R-2200A/HS, R2200AHS, 6625-01-182-0106, 01-182-0106, 6625011820106, 011820106

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 19 JUN 1984 01-182-0106

Cross Reference | NSN 6625-01-182-0106

Part Number Cage Code Manufacturer
R-2200A/HS 50012 MOTOROLA COMMUNICATIONS GROUP PARTS DEPT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-182-0106

Technical Data | NSN 6625-01-182-0106

Characteristic Specifications
TEST TYPE FOR WHICH DESIGNED POWER MEASUREMENT; DISTORTION; SIGNAL GENERATION; FREQ ERROR; MODULATION MEASUREMENT
AC VOLTAGE RATING 90.0 VOLTS MINIMUM AND 250.0 VOLTS MAXIMUM
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
DC VOLTAGE RATING 12.0 VOLTS NOMINAL
INTERNAL BATTERY ACCOMMODATION INCLUDED
INCLOSURE FEATURE SINGLE ITEM W/HOUSING
HEIGHT 7.500 INCHES NOMINAL
LENGTH 14.000 INCHES NOMINAL
WIDTH 12.500 INCHES NOMINAL
MAJOR COMPONENTS GENERATOR,SIGNAL; METER,SINAD; METER,DISTORTION; VOLTMETER; SYNTHESIZER; COUNTER; OSCILLOSCOPE
ACCESSORY COMPONENT QUANTITY 7
MANUFACTURERS CODE 50012
DESIGN CONTROL REFERENCE R-2200A/HS

Restrictions/Controls & Freight Information | NSN 6625-01-182-0106

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-01-182-0106

Category Code Description
Materiel Category and Inventory ManagerG Communications and Electronics Equipment, Electronics Materiel
Appropriation and Budget ActivityP Communications and Electronics Equipment (except Safeguard)
Management Inventory Segment1 REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance.
Specific Group/Generic CodeT Other Electronics Equipment
Weapons Systems/End Item or Homogeneous GroupTDTest Equip
Accounting Requirements CodeN Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items.
Source of SupplyB16US Army Communications-Electronics
Command and Fort Monmouth
Fort Monmouth, NJ 07703-5016
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeYCOMMUNICATION/ELECTRONIC EQUIPMENT AND PARTS
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1