Product Details | ELECTRICAL FREQUENCY METER

6625-00-649-4287 An instrument which measures the rate of regularly recurring variations in an electric current or voltage and is usually calibrated in Hertz (cycles per second or CPS). The value may be expressed by means of a pointer and calibrated dial vibrating reed or a digital read out display. For instruments which measure radio frequencies, see CALIBRATOR, FREQUENCY; and WAVEMENTER. Excludes: COUNTER ELECTRONIC DIGITAL.

Part Alternates: K125605, 59, 590030, 590-030, 590082, 590-082, 61419, 6625-00-649-4287, 00-649-4287, 6625006494287, 006494287

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1963 00-649-4287

Drawings & Photos | NSN 6625-00-649-4287


Cross Reference | NSN 6625-00-649-4287

Part Number Cage Code Manufacturer
59 28569 HICKOK INCORPORATED
590-030 28569 HICKOK INCORPORATED
590-082 28569 HICKOK INCORPORATED
590030 28569 HICKOK INCORPORATED
61419 99167 HAMILTON SUNDSTRAND CORPORATION
K125605 09301 KEARFOTT CORP SOMA FORWARDING DIV
K125605 88818 KEARFOTT CORPORATION DBA KEARFOTT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-649-4287

Technical Data | NSN 6625-00-649-4287

Characteristic Specifications
INSTALLATION DESIGN PANEL
(NON-CORE DATA) PANEL FOR WHICH DESIGNED NONMAGNETIC
(NON-CORE DATA) CIRCUIT CONSTRUCTION TYPE NONELECTRONIC
INDICATOR TYPE DIAL W/POINTER
MEASUREMENT RANGE 375.0 TO 425.0 HERTZ SINGLE INDICATOR SINGLE RANGE
ACCURACY IN PERCENT -0.33 TO 0.33 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
SCALE GRADUATION TYPE LINEAR SINGLE INDICATOR SINGLE RANGE
SCALE DIVISION QUANTITY 50 SINGLE INDICATOR SINGLE RANGE
POINTER COLOR BLACK SINGLE INDICATOR SINGLE RANGE
DIAL SCALE MARKING COLOR BLACK SINGLE INDICATOR SINGLE RANGE
BACKGROUND COLOR WHITE SINGLE INDICATOR SINGLE RANGE
MOVEMENT TYPE MOVING COIL, PERMANENT MAGNET
MOVEMENT SUSPENSION METHOD METAL PIVOT BASE
FREQUENCY RESPONSE RANGE 375.0 TO 425.0 HERTZ
CIRCUIT ATTACHMENT METHOD AND QUANTITY 1 CONNECTOR, RECEPTACLE
SENSITIVITY RATING 0.8 VOLT-AMPERES
SCALE SELECTION METHOD TERMINAL
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED AC
OPERATING VOLTAGE RATING IN VOLTS 100.0 AC MINIMUM AND 125.0 AC MAXIMUM
FREQUENCY RATING 60.000 HERTZ NOMINAL
PHASE SINGLE
STYLE DESIGNATOR C2 RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE 3.125 INCHES NOMINAL
METER DEPTH BEHIND MOUNTING FLANGE 3.28125 INCHES NOMINAL
OVERALL HEIGHT 3.250 INCHES NOMINAL
OVERALL LENGTH 3.406 INCHES NOMINAL
OVERALL WIDTH 3.250 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
MOUNTING HOLE DIAMETER 0.138 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLE E3 FOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.200 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.200 INCHES NOMINAL
MATERIAL STEEL
SURFACE TREATMENT ENAMEL
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
ENVIRONMENTAL PROTECTION DUSTPROOF AND SHOCK PROOF AND WATERPROOF
FURNISHED ITEMS AND QUANTITY LOCKING MTG INSERT 4
FEATURES PROVIDED ZERO ADJUSTER
SPECIAL FEATURES RUGGEDIZED
III FSC APPLICATION DATA TEST SET,ELECT. EQUIP.

Restrictions/Controls & Freight Information | NSN 6625-00-649-4287

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-00-649-4287

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each