NSN 6150-01-578-3256 MIL-C-29184/8, MIL-C-29184/8-01, MILC291848
Product Details | ELECTRICAL POWER CABLE ASSEMBLY
6150-01-578-3256 A definite continuous length of CABLE, POWER, ELECTRICAL having one or both ends processed and/or terminated in fittings which provide for connection to other items. Excludes CABLE AND CONDUIT ASSEMBLY, ELECTRICAL and items having branches or forks. See also WIRING HARNESS.20511150037Nuclear Warheads and Warhead Sections11350043Fuzing and Firing Devices, Nuclear Ordnance11900057Specialized Test and Handling Equipment, Nuclear Ordnance5995000061500055Miscellaneous Electric Power and Distribution Equipment
Part Alternates: MIL-C-29184/8, MIL-C-29184/8-01, MILC291848, MILC29184801, 6150-01-578-3256, 01-578-3256, 6150015783256, 015783256
Electric Wire, and Power and Distribution Equipment | Miscellaneous Electric Power and Distribution Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 01 OCT 2009 | 01-578-3256 | 00485 ( CABLE ASSEMBLY, POWER, ELECTRICAL ) |
Demand History | NSN 6150-01-578-3256
Part Number | Request Date | QTY | Origin |
---|---|---|---|
6150-01-578-3256 | 2015-08-223 | 1 | DIBBS-RFPs |
6150-01-578-3256 | 2012-01-18 | 32 | DIBBS |
6150-01-578-3256 | 2011-10-291 | 33 | DIBBS |
6150-01-578-3256 | 2011-02-43 | 82 | DIBBS |
6150-01-578-3256 | 2010-10-291 | 141 | DIBBS |
6150-01-578-3256 | 2010-10-288 | 165 | DIBBS |
6150-01-578-3256 | 2010-09-246 | 124 | DIBBS |
6150-01-578-3256 | 2010-07-193 | 45 | DIBBS |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6150-01-578-3256
Technical Data | NSN 6150-01-578-3256
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | RECEPTACLE AND STRIPPED |
SPECIAL MARKINGS | HAS TWO MARKING BANDS WHICH SHOULD BE PLACED ON CABLE ACCORDING TO FIGURE 1 OF MILITARY SPECIFICAITON |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
USAGE DESIGN | POWER |
CONDUCTOR QUANTITY | 8 |
PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE ASSEMBLY, POWER, ELECTRICAL |
SPECIAL FEATURES | FOR PORTABLE PANELBOARDS: TYPE IV, CLASS 1, 60 AMPERE;ASSY INCLUDES: MIL-C-22992, CLASS L, 60 AMPERES, CABLE CONNECTING RECEPTACLE CONNECTOR, WITHOUT COUPLING RING, QTY 1; PROTECTIVE COVER (CAP TYPE), QTY 1;CABLE STRAIN RELIEF GRIP, QTY 1;CABLE SEALING GLAND, QTY 1;PORTABLE POWER CABLE, NEMA TYPE G, 4 CONDUCTOR, NBR 6 AWG, WITH NOT LESS THAN 259 STRANDS PER CONDUCTOR;4 GROUNDING CONDUCTORS, NBR 12 AWG, WITH NOT LESS THAN 19 STRANDS PER CONDUCTOR, QTY 1;MARKING BANDS, QTY 2;END OPPOSITE CONNECTOR SHALL HAVE 8 INCHES OF THE OUTER JACKET AND 1 INCH OF INSULATION REMOVED FROM EACH CONDUCTOR;DIP BARE CONDUCTOR LEADS IN SOLDER;ELECTRICAL POWER 208Y/120 VOLT, 3-PHASE, 4-POLE, 5-WIRE |
VOLTAGE RATING | 120.0 SERVICE VOLTAGE ALL CONDUCTORS |
OVERALL LENGTH | 50.000 FEET |
FURNISHED ITEMS | CONNECTOR AND ELECTRICAL CONNECTOR COVER |
SPECIFICATION/STANDARD DATA | 81349-MIL-C-29184/8B, DTD 9 DEC 91 WITH NOTICE 3, DTD 17 NOV 2006 WHICH REMAINS INACTIVE FOR NEW DESIGN, HOWEVER IS VALID FOR USE GOVERNMENT SPECIFICATION |
END ITEM IDENTIFICATION | 5411-01-304-6122, SHELTER, NONEXPANDABLE |
Restrictions/Controls & Freight Information | NSN 6150-01-578-3256
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061130 | CABLE ASSEMBLY |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 743 | unknown |
Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6150-01-578-3256
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 6 | Critical Repair Part to a Non-Combat Essential End Item. Those parts or components whose failure in a noncombat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | F | Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level. |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |