Product Details | DISTRIBUTION BOX

6110-01-581-5626 An enclosure which includes mounts, and protects such items as switches, circuit breakers, jacks, fuseholders, connectors, terminals and/or terminal boards, resistors, capacitors, transformers, and the like. It is primarily designed to distribute electrical power from one or more primary power source(s) such as generator(s) and battery(ies) to one or more electrical and/or electronic item(s). It may include a cover or door. For enclosures which include only circuit breakers, switches, jacks, fuseholders, terminals and/or terminal boards, see CIRCUIT BREAKER BOX; SWITCH BOX; JACK BOX; FUSE BOX and TERMINAL BOX. For enclosure primarily designed to interconnect two or more electrical and/or electronic items, except primary power source(s) see INTERCONNECTING BOX. For empty boxes which are designed to mount, but do not include electrical devices such as switches, jacks, fuseholders, terminals and/or terminal boards, see JUNCTION BOX. See also INTERCONNECTING CABINET; CONTROL (as modified); PANEL (1) (as modified); RELAY ASSEMBLY; PANEL, POWER DISTRIBUTION; SWITCHBOARD (as modified) and PANEL, FUSE. Excludes CONNECTOR-SWITCH.

Part Alternates: 11232805, 112-32805, 6110-01-581-5626, 01-581-5626, 6110015815626, 015815626

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 21 JAN 2010 01-581-5626

Cross Reference | NSN 6110-01-581-5626

Part Number Cage Code Manufacturer
112-32805 61099 LEIDOS, INC. DBA NATIONAL SECURITY SECTOR

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-01-581-5626

Technical Data | NSN 6110-01-581-5626

Characteristic Specifications
PART NAME ASSIGNED BY CONTROLLING AGENCY 1RU EMI 8-CIRCUIT POWER DISTRIBUTION ASSY (PDA)
END ITEM IDENTIFICATION 112-32805(61099), POWER DISTRIBUTION ASSEMBLY
SPECIAL FEATURES PDA FITS EIA STD 19 INCH RACK AND INCLUDES CABLE TREATMENT FOR EASE OF ACCESS WHEN USING STD GCCS-M, ISNS AND TIDS RACK VERSION THERMAL ALARMS, INCLUDES BATTLE SHORT OVERRIDE CIRCUIT AND UPS INTERFACE.

Restrictions/Controls & Freight Information | NSN 6110-01-581-5626

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063160 SWITCH BOXES/ELEC ENCLOSURES
Less than car load rating W Rating Variable
Less than truck load rating W Rating Variable
Water commodity Code 576 unknown
Originating Activity Code HD Naval Inventory Control Point
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-01-581-5626

Category Code Description
Cognizance Codes7GDepot level reparable electronic material to support
Naval Inventory Control Point, Space and Naval Warfare Systems Command, Mechanicsburg
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesHDIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative