NSN 6110-00-483-7049 196890, 1968-90, 4214121
Product Details | VOLTAGE REGULATOR
6110-00-483-7049 A component within a single inclosure or provided with a single mounting specifically designed to control automatically the voltage output of an electrical system within certain required limits, regardless of variations of the effective load or of input voltages within a specific range. Does not include items in which regulation is accomplished solely by transformer action. See also REGULATOR SET, VOLTAGE. Excludes REGULATOR, ENGINE GENERATOR.20259630018Electronic Modules61100028Electrical Control Equipment
Part Alternates: 196890, 1968-90, 4214121, 421412-1, 6110-00-483-7049, 00-483-7049, 6110004837049, 004837049
Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 18 JUN 1974 | 00-483-7049 | 00176 ( REGULATOR, VOLTAGE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6110-00-483-7049
Related Products | NSN 6110-00-483-7049
Technical Data | NSN 6110-00-483-7049
Characteristic | Specifications |
---|---|
REGULATION METHOD | ELECTRONIC |
ELECTRONIC DEVICE TYPE | SOLID STATE |
CIRCUIT TYPE | SERIES |
INPUT CURRENT TYPE | DC |
INPUT VOLTAGE RATING IN VOLTS | 22.0 MINIMUM AND 28.0 MAXIMUM |
OUTPUT CURRENT TYPE | DC |
OUTPUT VOLTAGE RATING IN VOLTS | 11.0 MINIMUM AND 13.0 MAXIMUM |
POWER RATING | 20.0 WATTS NOMINAL |
RECOVERY TIME | NOT RATED |
OPERATING TEMP RANGE | NOT RATED |
OVERALL WIDTH | 2.500 INCHES MAXIMUM |
OVERALL THICKNESS | 1.500 INCHES MAXIMUM |
OVERALL LENGTH | 3.750 INCHES MAXIMUM |
MOUNTING METHOD | UNTHREADED HOLES |
MOUNTING HOLE QUANTITY | 2 |
MOUNTING HOLE DIAMETER | 0.223 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES | 2.750 INCHES NOMINAL |
SPECIAL FEATURES | INCLUDES 3LEADS OF 16 AWG STRANDED WIRES 13.000 IN. LG |
MANUFACTURERS CODE | 1T9K5 |
DESIGN CONTROL REFERENCE | 1968-90 |
Restrictions/Controls & Freight Information | NSN 6110-00-483-7049
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 062920 | REGULATORS INDUCTION/VOLTAGE |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | CX | Defense Supply Center Richmond Richmond, VA 23297-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6110-00-483-7049
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Echelon Identification Code | B | Consumable Repair Parts |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |