NSN 5996-01-147-6054 SMD867928, SM-D-867928, 01-147-6054
Product Details | INTERMEDIATE FREQUENCY AMPLIFIER
5996-01-147-6054 An electronic device whose input signals controls a local source of power and delivers an output signal of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It is tuned to a single fixed frequency which is the resultant of heterodyne action between a local oscillator frequency and a signal frequency introduced from an external source.
Part Alternates: SMD867928, SM-D-867928, 5996-01-147-6054, 01-147-6054, 5996011476054, 011476054
Electrical and Electronic Equipment Components | Amplifiers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 18 FEB 1983 | 01-147-6054 | 00885 ( AMPLIFIER, INTERMEDIATE FREQUENCY ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5996-01-147-6054
Related Products | NSN 5996-01-147-6054
Technical Data | NSN 5996-01-147-6054
Characteristic | Specifications |
---|---|
CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
OPERATING CONTROL METHOD | AUTOMATIC |
CONTROL TYPE | LOCAL |
AVERAGE LIFE MEASUREMENT | NOT RATED |
CONNECTION TYPE AND LOCATION | CONNECTOR, PLUG TOP |
CONNECTION CONTACT TYPE AND QUANTITY | 1 CONNECTOR, PLUG EXTERNAL |
INCLOSURE TYPE | OPEN |
Restrictions/Controls & Freight Information | NSN 5996-01-147-6054
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063035 | SETS RADIO/TV AND RELATED ARTICLES |
Less than car load rating | ||
Less than truck load rating | G | 125.0 |
Water commodity Code | 758 | unknown |
Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5996-01-147-6054
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | H | If condemned or uneconomically repairable, then dispose at Intermediate level. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |