Product Details | INTERMEDIATE FREQUENCY AMPLIFIER

5996-00-665-0023 An electronic device whose input signals controls a local source of power and delivers an output signal of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It is tuned to a single fixed frequency which is the resultant of heterodyne action between a local oscillator frequency and a signal frequency introduced from an external source.

Part Alternates: A6265, A62650, A6265D, 5996-00-665-0023, 00-665-0023, 5996006650023, 006650023

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-665-0023

Drawings & Photos | NSN 5996-00-665-0023


Cross Reference | NSN 5996-00-665-0023

Part Number Cage Code Manufacturer
A6265 80249 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
A62650 84902 FORMED PLASTICS INC.
A6265D 80249 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-00-665-0023

Technical Data | NSN 5996-00-665-0023

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE ELECTRON TUBE
FREQUENCY PER CHANNEL 60.0 MEGAHERTZ NOMINAL OPERATING CHANNEL
SWITCHING RATE PER SECOND ANY ACCEPTABLE
FREQUENCY SHIFT ANY ACCEPTABLE
FREQUENCY ADJUSTMENT TYPE CONTINUOUS
VARIATION FREQUENCY RATING IN DECIBELS ANY ACCEPTABLE
PHASE SHIFT ANGLE IN DEG ANY ACCEPTABLE
INTERMEDIATE FREQUENCY BANDPASS 4.4 MEGAHERTZ
ATTENUATION IN DECIBELS NOT RATED
AVERAGE POWER RATING PER CHANNEL NOT RATED
SIGNAL VOLTAGE RATING PER CHANNEL 6.000 MICROVOLTS NOMINAL INPUT 2.000 VOLTS NOMINAL OUTPUT
OVERALL GAIN 110.0 DECIBELS
IMPEDANCE RATING PER CHANNEL 93.000 OHMS INPUT CHANNEL 1.500 KILOHMS OUTPUT CHANNEL
DISTORTION TYPE AND PERCENT ANY ACCEPTABLE
OPERATING CONTROL METHOD AUTOMATIC
CONTROL TYPE REMOTE
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS NOT RATED
AVERAGE LIFE MEASUREMENT NOT RATED
MAXIMUM OPERATING ALTITUDE RATING NOT RATED
OPERATING TEMP RANGE NOT RATED
VIBRATION RESISTANCE RANGE IN HERTZ NOT RATED
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS NOT RATED
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 150.0 NOMINAL 1ST VOLTAGE
EXTERNAL AC OPERATING VOLTAGE IN VOLTS 6.3 NOMINAL 2ND VOLTAGE
OPERATING AC FREQUENCY IN HERTZ 60.0 NOMINAL SINGLE VOLTAGE
PHASE SINGLE
CONNECTION TYPE AND LOCATION INTEGRAL CABLE W/COAXIAL PLUG TOP
CONNECTION CONTACT TYPE AND QUANTITY ANY ACCEPTABLE
INCLOSURE TYPE OPEN
ENVIRONMENTAL PROTECTION GENERAL PURPOSE
INSTALLATION DESIGN FREE-STANDING
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 13.843 INCHES NOMINAL
OVERALL HEIGHT 2.625 INCHES NOMINAL
OVERALL WIDTH 2.875 INCHES NOMINAL
IDENTIFICATION DESIGNATOR A6265D-27876
SPECIAL FEATURES INCLUDES ONE SET OF TUBES AND ONE COAX CABLE
III FSC APPLICATION DATA RADIO,EXCEPT NAVIGATION,NONAIRBORNE
MANUFACTURERS CODE 80249
DESIGN CONTROL REFERENCE A6265D

Restrictions/Controls & Freight Information | NSN 5996-00-665-0023

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:CMunitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating
Less than truck load rating G 125.0
Water commodity Code 758 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5996-00-665-0023

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each