NSN 5996-00-086-8720 5280076005, 528-0076-005, 00-086-8720
Product Details | INTERMEDIATE FREQUENCY AMPLIFIER
5996-00-086-8720 An electronic device whose input signals controls a local source of power and delivers an output signal of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It is tuned to a single fixed frequency which is the resultant of heterodyne action between a local oscillator frequency and a signal frequency introduced from an external source.
Part Alternates: 5280076005, 528-0076-005, 5996-00-086-8720, 00-086-8720, 5996000868720, 000868720
Electrical and Electronic Equipment Components | Amplifiers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1963 | 00-086-8720 | 00885 ( AMPLIFIER, INTERMEDIATE FREQUENCY ) |
Cross Reference | NSN 5996-00-086-8720
Part Number | Cage Code | Manufacturer |
---|---|---|
528-0076-005 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5996-00-086-8720
Related Products | NSN 5996-00-086-8720
Technical Data | NSN 5996-00-086-8720
Characteristic | Specifications |
---|---|
CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
FREQUENCY PER CHANNEL | 500.0 KILOHERTZ NOMINAL OPERATING CHANNEL |
SWITCHING RATE PER SECOND | ANY ACCEPTABLE |
FREQUENCY SHIFT | ANY ACCEPTABLE |
FREQUENCY ADJUSTMENT TYPE | CONTINUOUS |
VARIATION FREQUENCY RATING IN DECIBELS | 3.0 |
PHASE SHIFT ANGLE IN DEG | ANY ACCEPTABLE |
INTERMEDIATE FREQUENCY BANDPASS | 3.0 KILOHERTZ |
ATTENUATION IN DECIBELS | NOT RATED |
AVERAGE POWER RATING PER CHANNEL | NOT RATED |
SIGNAL VOLTAGE RATING PER CHANNEL | 100.000 VOLTS NOMINAL INPUT 778.000 MILLIVOLTS NOMINAL OUTPUT |
OVERALL GAIN | NOT RATED |
IMPEDANCE RATING PER CHANNEL | 50.000 OHMS INPUT CHANNEL 600.000 OHMS OUTPUT CHANNEL |
DISTORTION TYPE AND PERCENT | ANY ACCEPTABLE |
OPERATING CONTROL METHOD | AUTOMATIC |
CONTROL TYPE | REMOTE |
INDICATOR DEVICE TYPE AND QUANTITY | ANY ACCEPTABLE |
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | NOT RATED |
AVERAGE LIFE MEASUREMENT | NOT RATED |
MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
OPERATING TEMP RANGE | NOT RATED |
VIBRATION RESISTANCE RANGE IN HERTZ | NOT RATED |
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | NOT RATED |
EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 20.0 NOMINAL SINGLE VOLTAGE |
CONNECTION TYPE AND LOCATION | RECEPTACLE, COAXIAL REAR |
CONNECTION CONTACT TYPE AND QUANTITY | 1 RECEPTACLE, COAXIAL EXTERNAL |
INCLOSURE TYPE | ENCASED |
ENVIRONMENTAL PROTECTION | DUSTPROOF |
INSTALLATION DESIGN | MECHANICAL |
BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
OVERALL LENGTH | 4.250 INCHES NOMINAL |
OVERALL HEIGHT | 3.915 INCHES NOMINAL |
OVERALL WIDTH | 2.953 INCHES NOMINAL |
III FSC APPLICATION DATA | AMPLIFIER,INTERMEDIATE FREQ,RADIO,EXCEPT NAVIGATION,NONAIRBORNE |
MANUFACTURERS CODE | 13499 |
DESIGN CONTROL REFERENCE | 528-0076-005 |
Restrictions/Controls & Freight Information | NSN 5996-00-086-8720
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063035 | SETS RADIO/TV AND RELATED ARTICLES |
Less than car load rating | ||
Less than truck load rating | G | 125.0 |
Water commodity Code | 758 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5996-00-086-8720
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |