Product Details | ELECTRICAL RESOLVER

5990-00-762-8050 An item consisting of a rotor and a stator inductively coupled. It usually has two rotor windings displaced from each other by 90 degrees and two stator windings similarly displaced. The output voltage(s) is a trigonometric function of the input voltage(s) and the angular displacement of the rotor with respect to the stator. See also SYNCHRO (as modified) and GONIOMETER, ELECTRICAL. Excludes TRANSOLVER, ELECTRICAL and potentiometer sine/cosine electrical resolvers.

Part Alternates: 27PP1, 27RD10, 27RD-10, 4660032001, 466-0032-001, 5990-00-762-8050, 00-762-8050, 5990007628050, 007628050

Electrical and Electronic Equipment Components | Synchros and Resolvers

Supply Group (FSG) NSN Assign. NIIN
59 20 FEB 1970 00-762-8050

Drawings & Photos | NSN 5990-00-762-8050


Demand History | NSN 5990-00-762-8050

Part Number Request Date QTY Origin
27PP1 2020-07-195 5 US

Cross Reference | NSN 5990-00-762-8050

Part Number Cage Code Manufacturer
27PP1 08719 DUCOMMUN LABARGE TECHNOLOGIES, INC DBA AMERICAN ELECTRONICS
27RD-10 10112 GENERAL DYNAMICS GLOBAL IMAGING TECHNOLOGIES, INC.
466-0032-001 94756 BOEING COMPANY, THE DBA BOEING

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5990-00-762-8050

Technical Data | NSN 5990-00-762-8050

Characteristic Specifications
STATOR INPUT VOLTAGE RATING IN VOLTS 0.5 MINIMUM AND 10.0 MAXIMUM
FREQUENCY IN HERTZ 4800.0 NOMINAL
TRANSFORMATION RATIO 1.000 STATOR TO ROTOR NOMINAL
BODY STYLE A13 PICK-OFF A
OVERALL LENGTH 0.4500 INCHES MAXIMUM
BODY DIAMETER 2.6245 INCHES MINIMUM AND 2.6250 INCHES MAXIMUM
BODY THRU-HOLE DIAMETER 1.5000 INCHES MINIMUM AND 1.5005 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 8 WIRE LEAD
BODY MATERIAL ANY ACCEPTABLE
III FRAGILITY FACTOR MODERATELY RUGGED

Restrictions/Controls & Freight Information | NSN 5990-00-762-8050

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 659 unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5990-00-762-8050

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeAHSU:LGM-30 MINUTEMAN
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each