Product Details | WAVEGUIDE ADAPTER

5985-01-560-9034 An item designed to establish the necessary accommodations to connect a waveguide to a coaxial line, or to connect two or more terminated waveguides whose physical design does not normally allow connection.

Part Alternates: 5399381, 539938-1, 5985-01-560-9034, 01-560-9034, 5985015609034, 015609034

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 19 FEB 2008 01-560-9034

Drawings & Photos | NSN 5985-01-560-9034


Cross Reference | NSN 5985-01-560-9034

Part Number Cage Code Manufacturer
539938-1 96214 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-560-9034

Technical Data | NSN 5985-01-560-9034

Characteristic Specifications
STYLE DESIGNATOR D9 WAVEGUIDE TO COAXIAL
ADAPTER OVERALL HEIGHT 0.720 INCHES MAXIMUM
MATERIAL STEEL COMP 303 SINGLE TUBING SEGMENT ALUMINUM ALLOY 6061 SINGLE FLANGE
FLANGE QUANTITY 1
FLANGE STYLE C28 COVER TYPE SINGLE FLANGE
COAXIAL CONNECTOR SERIES DESIGNATION SMA
VOLTAGE STANDING WAVE RATIO 1.25

Restrictions/Controls & Freight Information | NSN 5985-01-560-9034

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information